English
Language : 

FN660-1-06 Datasheet, PDF (1/4 Pages) List of Unclassifed Manufacturers – Two-stage general performance EMI filter
Two-stage general performance
EMI filter
1-phase filters
FN 660
n Rated currents from 1 to 20A
n High differential and common-mode
attenuation
n Optional medical versions (B type)
Approvals
Technical specifications
Maximum continuous operating voltage:
Operating frequency:
Rated currents:
High potential test voltage:
Temperature range (operation and storage):
Flammability corresponding to:
Design corresponding to:
MTBF @ 40°C/230V (Mil-HB-217F):
250VAC, 50/60Hz
dc to 400Hz
1 to 20A @ 40°C max.
P –> E 2000VAC for 2 sec
P –> E 2500VAC for 2 sec (B types)
P –> N 760VAC for 2 sec
-25°C to +100°C (25/100/21)
UL 94V-2 or better
UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939
350,000 hours
Typical electrical schematic
Cx L
Cy Cx R L1
P
P‘
E
N
Line
N‘
Load
Features and benefits
n FN 660 two-stage filters are designed for
easy and fast chassis mounting.
n FN 660 filters are also available as B
versions without Y-capacitors for medical
applications with necessity for low leakage
currents.
n All filters provide a high
conducted attenuation performance, based
on chokes with high saturation resistance
and excellent thermal behavior.
n FN 660 filters are designed for noisy
applications requiring good differential
and common-mode attenuation.
n Various terminal options allow you to
select the desired connection style.
n FN 660 filters are also available as single-
stage filters (FN 610, FN 612 series).
n Custom-specific versions on request.
Typical applications
n Electrical and electronical equipment
n Consumer goods
n Power supplies
n Building automation
n Medical equipment
n Office automation equipment
n Datacom equipment