FN393-6-05-11 Datasheet, PDF (1/3 Pages) List of Unclassifed Manufacturers – Versatile fi ltered power entry module | |||
|
Versatile ï¬ltered power entry module
IEC inlet ï¬lters
FN 390
â Rated currents up to 10A
â For one or two fuses
â Fuses Ã6.3 x 32mm or Ã5 x 20mm
â 2-pole rocker switch
â Voltage selector
â Optional earth line choke (E type)
Approvals
Technical specifications
Typical electrical schematic
Maximum continuous operating voltage:
250VAC, 50/60Hz
Standard types
Operating frequency:
Rated currents:
50 to 400Hz
1 to 10A @ 40°C max.
Cx R 2xL1 Cx1 2xCy
High potential test voltage:
P â> E 2000VAC for 2 sec
N
Protection category:
P â> N 760VAC for 2 sec
IP40 according to IEC 60529
E
Temperature range (operation and storage):
-25°C to +85°C (25/85/21)
Design corresponding to:
UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939
P
Line
Load
Flammability corresponding to:
UL 94V-2 or better
MTBF @ 40°C/230V (Mil-HB-217F):
2,200,000 hours
E types
Voltage selector description:
Function:
Voltage marking:
Series:
Parallel:
Rocker switch description:
Function:
Electrical specifications:
Mechanical life:
Switch ratings:
USA (UL):
Canada (CSA):
Europe (ENEC):
Series/parallel
Cx R 2xL1 Cx1 2xCy
N
110-120V
E
220-240V
P
2-pole, dark not illuminated
Line
Load
Marking I - 0
Inrush current 51A
L2
6,000 on-off operations according to UL 1054, TV 5
10,000 on-off operations according to ENEC
50,000 cycles
10A, 125VAC; 1/3HP; 10A, 250VAC; 1/2HP
6A, 125VAC; 4A, 250VAC; 1/10HP
10A (4A), 250VAC*
* Value in () relates to the inductive current charge: cos γ = 0.65
The FN 390 power entry module combines
an IEC inlet, mains filter with single or
dual-fuse holder, voltage selector and 2-pole
rocker switch. Choosing FN 390 product
line brings you the rapid availability of a
standard filter associated with the necessary
safety acceptances. Standard IEC connector
filters are a practical solution helping you to
pass EMI system approval in a short time.
Multiple options designed to offer you the
desired solution.
Features and benefits
â High conducted attenuation performance,
based on chokes with high saturation
resistance and excellent thermal behavior.
â Rear or front mounting.
â Single or dual-fuse holder.
â USA Ã6.3 x 32mm or EU Ã5 x 20mm fuses.
â 2-pole rocker switch.
â Voltage selector 110-120V / 220-240V.
â Custom-specific versions are available on
request.
Typical applications
â Portable electrical and electronic
equipment
â Consumer goods
â EDP and office equipment
â Single-phase power supplies, switch-mode
power supplies
â Test and measurement equipment
|
▷ |