FN261-10-06 Datasheet, PDF (1/2 Pages) List of Unclassifed Manufacturers – General-purpose power entry module | |||
|
General-purpose power entry module FN 9260
⢠up to 10A current ratings
⢠IEC 950-compliant
⢠for one or two fuses (Ã5 x 20mm)
⢠optional medical version (B type)
⢠Nennstrom bis 10A
⢠IEC 950 konform
⢠Für eine oder zwei Sicherungen (Ã5 x 20mm)
⢠Für medizinische Geräte als Option (Typ B)
⢠courants de service pouvant atteindre 10A
⢠conforme à CEI 950
⢠pour un ou deux fusibles (Ã5 x 20mm)
⢠version médicale en option (type B)
Filter selection table
Choose the family FN xxx with the required body style and features, and add -?? to
determine current rating, and /?? for output connections. Example: FN 9260-1/06 is a
horizontal screw-mounting filter for twin fuses, rated for 1A, with fast-on outputs.
Approvals
Family
FN 261 -?? /??
FN 261S -?? /??
FN 9260 -?? /??
FN 9260S -?? /??
1 (1.2)
-1
-1
-1
-1
5.3
Current ratings
A at 40ËC (25Ë)
2 (2.3)
4 (4.6)
6 (6.9)
-2
-4
-6
-2
-4
-6
-2
-4
-6
-2
-4
-6
Inductance L mH
2.7
1
0.3
Output connection
10 (11.5)
-10
/06
-10
/06
-10
/06
-10
/06
0.2
EN 133200
IEC 60939
Housing
-
-
-
-
For fuse(s)
Nbr.
1
1
2
2
Additional specifications
Filter type
Capacitance
Maximum
Res.
Cx
Cy
leakage
R
nF
nF µA/phase
Mâ¦
All standard types
100 2.2
190
1
FN 9260B types (medical) 100 -
2
1
MTBF at 40ËC, 230V, per Mil-HB-217F: 2,200,000 hours
Weight
g
50
50
Maximum
operating volt.
VAC Hz
Operating
frequency
Hz
Hipot test voltage
PN¤E P¤N
VAC VDC
250 50/60 DC to 400 2000 1700
250 50/60 DC to 400 2500 1700
Electrical schematics
FN 9260 (B-types without Cy capacitors)
Cx
R
2xL
N
E
P
See tables for component values
2xCy
N'
E'
P'
78
FN 261
N
E
P
Cx
R
2xL
2xCy
N'
E'
P'
|
▷ |