English
Language : 

FN2060-6-06 Datasheet, PDF (1/5 Pages) List of Unclassifed Manufacturers – Multi-stage General Purpose EMI Filter
Multi-stage General Purpose EMI Filter
1-phase Filters
FN 2060
n Rated currents from 1 to 30A
n High differential and common-mode
attenuation
n Optional medical versions (B type)
n Optional safety versions (A type)
Approvals
Technical specifications
Maximum continuous operating voltage:
Operating frequency:
Rated currents:
High potential test voltage:
Temperature range (operation and storage):
Flammability corresponding to:
Design corresponding to:
MTBF @ 40°C/230V (Mil-HB-217F):
250VAC, 50/60Hz
dc to 400Hz
1 to 30A @ 40°C max.
P –> PE 2000VAC for 2 sec
P –> PE 2500VAC for 2 sec (B types)
P –> N 1100VDC for 2 sec
-25°C to +100°C (25/100/21)
UL 94V-2 or better
UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939
950,000 hours
1,650,000 hours (B types)
Typical electrical schematic
Cx L R Cx
L
P
N
PE
Line
Cy Cy
P‘
N‘
Load
Features and benefits
n FN 2060 two-stage filters are designed for
easy and fast chassis mounting.
n FN 2060 filters are also available as B
versions without Y-capacitors for medical
applications as well as A version with low
capacitance for safety critical applications
with necessity for low leakage currents.
n All filters provide a high conducted
attenuation performance, based on chokes
with high saturation resistance and
excellent thermal behavior.
Typical applications
n FN 2060 two-stage filters are designed for n Electrical and electronic equipment
noisy applications requiering good
n Consumer goods
differential and common-mode attenuation. n Household equipment
n FN 2060 filters are also available as single- n Building automation
stage filters (FN 2010 series).
n Industrial applications
n Various terminal options allow you to
n Machinery
select the desired connection style.
n Medical equipment
n Electronic data processing equipment
n Office automation and datacom equipment
n Various noisy applications requiering good
filter performance