English
Language : 

FN2060-30-08 Datasheet, PDF (1/2 Pages) List of Unclassifed Manufacturers – General-purpose filter
General-purpose filter
FN 2020
• Current ratings from 1 to 60A
• High differential mode attenuation
• Optional medical versions (B types)
• Optional safety versions (A types)
• Nennströme von 1 bis 60A
• Hohe Dämpfung im symmetrischen Betrieb
• Optionale medizinische Versionen (Typ B)
• Optionale Sicherheitsversionen (Typ A)
• Courants de service de 1 à 60 A
• Bonne atténuation en mode différentiel
• En option version pour appareils médicaux (type B)
• En option version pour la sécurité (type A)
Filter selection table
Choose the filter FN xxxx-x with the required current rating and features, and add /??
to determine input/output (line/load) connection style. Example: FN 2020-10/06 is a 10A
filter with fast-on connections.
Approvals
Filter
Connections
FN 2020 -1 /?? /06 /07
FN 2020 -3 /?? /06 /07
FN 2020 -6 /?? /06 /07
FN 2020 -10 /?? /06 /07
FN 2020 -12 /?? /06 /07
FN 2020 -16 /?? /06 /07
FN 2020 -20 /?? /06
/08
FN 2020 -30 /??
/08
FN 2020 -60 /??
/24
Current ratings
at 40°C (25°)
A
1 (1.15)
3 (3.45)
6 (6.9)
10 (11.5)
12 (13.8)
16 (18.4)
20 (23)
30 (34.5)
60 (69)
Inductance
L
mH
12
2.5
1
0.8
0.7
0.65
0.6
0.67
1
Capacitance
Cx
Cy
μF
nF
0.15 4.7
0.15 4.7
0.15 4.7
0.15 4.7
0.15 4.7
0.15 4.7
0.15 4.7
0.47 10
1.5
10
Resistance
R
MΩ
1
1
1
1
1
1
1
0.47
0.22
Housing
F2
F2
F2
F2
F2
H2
K1
P
L2
Weight
g
80
80
80
85
85
140
210
470
1100
Additional specifications
Filter type
Standard types
B medical types (no Y capacitors)
A safety types (lower capacitance)
Electrical schematic
FN 2020 Cx R
P
L
Cx
Maximum
operating voltage
VAC Hz
250 50/60
250 50/60
250 50/60
Operating
frequency
Hz
DC to 400
DC to 400
DC to 400
Hipot test voltage
PN E P N
VAC VDC
MTBF
Maximum
Per Mil-HB-217F at 40ºC 230V leakage
hours
mA/phase
2000
2500
2500
1700
1700
1700
1 000 000
1 750 000
1 000 000
0.4*
0.002
0.040
* 1mA for 30A and 60A versions
P'
N
N'
E
Cy Cy
See tables for component values.
106