English
Language : 

FKA01X724 Datasheet, PDF (1/3 Pages) List of Unclassifed Manufacturers – 24 x 48 digital counters
Counters
24 x 48 digital counters
Types FKA01, FKA02, FKA03
• 8-digit LCD display
• 8 mm digits
• Reset button with locking function
• 8 years battery lifetime
• 2 inputs (FKA01, FKA02); 1 input (FKA03)
• Up-down counting mode (through electrical control)
• For front panel mounting
• 24 x 48 mm housing
• Filter function for bounce-free counting with mechan-
ical contacts
Product Description
Ordering Key
24 x 48 mm up to 2 inputs
up-down counters for flush
mounting. NPN, PNP or volt-
age inputs allow connection
to any type of sensors or
Type Selection
open collector output. The
front key, which can be
locked, allows fast and easy
counting reset.
Housing
Function
Type
Item number
Output
Input range
FKA 01 X 724
Mounting
Front panel
Front panel
Front panel
Input
NPN or voltage free contact
NPN, PNP or voltage free contact
Voltage
Counting mode
Adding/Substracting
Adding/Substracting
Adding
Max. couting
freqency
7 KHz
12 KHz
30 Hz
Model
FKA01X724
FKA02X724
FKA03XW24
Input Specifications
Input A (FKA01)
Input type
Low level
High level
Max counting frequency
Input resistance
Input A (FKA02)
Input type
Low level
High level
Max counting frequency
Input resistance
Input A (FKA03)
Input type
Low level
High level
Min pulse time
Max counting frequency
Input resistance
Input B (FKA01, FKA02)
Input type
Low level
High level
Max counting frequency
Input resistance
NPN open collector or
voltage free contact
0 to 0,7 V DC
3 to 30 V DC
7 kHz
≈1 MΩ
PNP open collector or
voltage free contact
0 to 0,7 V DC
4 to 30 V DC
12kHz
≈100 kΩ
Voltage (10 to 260 V AC/DC)
(galvanic insulation)
0 to 2 V AC/DC
10 to 260 V AC/DC
16 ms
30 Hz
≈160 kΩ
NPN open collector or
voltage free contact
0 to 0,7 V DC
3 to 30 V DC
30 Hz
≈1 MΩ
Input B (Reset) (FKA03)
Input type
Low level
High level
Min pulse time
Max counting frequency
Input resistance
Voltage (10 to 260 V AC/DC)
(galvanic insulation)
0 to 2 V AC/DC
10 to 260 V AC/DC
16 ms
30 Hz
≈160 kΩ
Reset (FKA01, FKA02)
Input type
Low level
High level
Min pulse time
Input resistance
NPN open collector or
voltage free contact
0 to 0,7 VDC
3 to 30 V DC
50 ms
≈2 MΩ
Electrical locking of the reset
key
Input type
NPN open collector or
voltage free contact
Low level
0 to 0,7 V DC
High level
3 to 5 V DC
Input not active
Reset key locked
Input in contact with GND Reset key unlocked
Input resistance
≈2,2 MΩ
Operating mode switch (FKA01, FKA02)
Input type
NPN open collector or
voltage free contact
Low level
0 to 0,7 V DC
Hight level
3 to 5 V DC
Input not active
Adding mode
Input in contact with GND Subtracting mode
Input resistance
≈2,2 MΩ
Specifications are subject to change without notice (13.09.06)
1