English
Language : 

ENS0575 Datasheet, PDF (1/8 Pages) List of Unclassifed Manufacturers – This specification describes the requirements of 650W/750Watts switching power
En_h_a_n_c_e_E_l_e_c_tr_o_n_ic_s_C__o_.,_L_T_D________________________________________________P_r_o_d_u_c_t_S_p_e_c_if_i_ca_t_ion
MODEL NO. ENS0575 (ACTIVE PFC)
This specification describes the requirements of 650W/750Watts switching power
supply with an stretch form-factor and EPS12V, +5V standby voltage,remote on/off
control, dual line input capability and forced air cooling characteristics .
) 1. AC INPUT
1.1 AC input requirements
The input voltage, current, and frequency requirements for continuous
operation are stated below.
750WTable 1 AC Input Line Requirements
Parameter
Min.
Vin( Full range )
103
Vin Frequency
47
Iin
Nom.
115---240
60----50
10-----5
Max.
264
63
650WTable 1 AC Input Line Requirements
Parameter
Min.
Nom.
Vin( Full range )
90
100---240
Vin Frequency
47
60----50
Iin
10-----5
Power factor correction (PF)>0.95 at full load.
Max.
264
63
1.2 Inrush current regulation
50 A @ 115Vrms
100 A @ 230Vrms (at 25OC ambient cold start).
) 2. DC OUTPUT
2.1 DC voltage regulation
Parameter
+3.3V
+5V
+12V1
+12V2
+12V3
+12V4
-12V
+5VSB
Range
+/-5%
+/-5%
+/-5%
+/-5%
+/-5%
+/-5%
+/-10%
+/-5%
Min
+3.14
+4.75
+11.4
+11.4
+11.4
+11.4
-10.8
+4.75
Nom.
+3.3
+5
+12
+12
+12
+12
-12
+5
Max
+3.47
+5.25
+12.6
+12.6
+12.6
+12.6
-13.2
+5.25
Unit
VACrms
Hz
Arms
Unit
VACrms
Hz
Arms
Unit
Volts
Volts
Volts
Volts
Volts
Volts
Volts
Volts
AUDIT:________李復新________CHECK:________余朝波_______DESIGN:__________張炳蘭______
ENS0575.SPEC
REV:1.1
1 OF 8
2006/07/04