ENR0560 Datasheet, PDF (1/9 Pages) List of Unclassifed Manufacturers – This specification defines the performance characteristics of a single-phase 600 watt power supply
E_n_h_an_c_e__E_le_c_tr_o_n_i_cs__C_o_.,_L_T_D__________________________________________________P_r_o_d_u_ct_S__p_ec_i_fi_c_a_ti_on
MODEL NO. ENR0560 SERIES (ACTIVE PFC)
This specification defines the performance characteristics of a single-phase (3-wire) 600 watt power supply with
wide range input AC capability (100-240VAC/50-60Hz) under operation temperature 50 degree C. The power
supply shall be designed for parallel operation. In the event of a power supply failure, the redundant power supply
continues to power the system. The number of power supplies per system will be limited to a maximum of two.
The power supply shall be designed for “hot swap” exchange and contain the OR-ing isolation MOSFETs
for all outputs and shall communicate to external devices through Inter-Integrated (I2C) Circuit protocol. The
power supply will have an EEPROM for storing powers supply FRU information.
F1. Input Requirement
1.1 AC input requirements
The Power supply must be having a universal power input with active power correction to reduce the line harmonics
in accordance with the EN61000-3-2 standard.
The power supply must be capable of operating with the following Conditions
Parameter
Min
Nom.
Max
Unit
Vin
90
100
240
264
VACrms
Vin Frequency
47
50
60
63
Hz
Iin
8
4
A
1.2 Power Factor
Power factor correction (PF)>0.9 at full load.
1.3IInnrruushshCcuurrrernetnt regulation
When input power is applied to the power supply any initial current surge or spike of 10ms or less will not
exceed 25A peak. Any additional inrush current surges or spikes in the form of AC cycles or multiple AC
cyclesthan 10ms, greater and less than 150ms, must not exceed 15A peak. After 150ms the AC input current
must meet the requirements in Section
1.3.2 It is acceptable that AC line inrush current may reach up to 60A peak within 1 ms caused by capacitors
of EMI filter.
1.3.3 Hot Inrush Current
Not applicable
Note: For any conditions during turn-on the inrush current will not open the primary input fuse or damage any other
components.
1.4 Efficiency
The Power supply efficiency typical 85% at 230VAC/50Hz and full load without Fan.