English
Language : 

ENP7000 Datasheet, PDF (1/10 Pages) List of Unclassifed Manufacturers – specification describes the requirements of 200,220,250,275Watts with full range voltage,275W with 230Vac only voltage switching power supply
Enhance El_e_c_tr_o_n_ic_s__C_o_.,_L_T_D___________________________________________________________P_r_o_d_u_c_t_S_pecification
MODEL NO. ENP7000 SERIES (ACTIVE PFC)
This specification describes the requirements of 200,220,250,275Watts with full range voltage,
275W with 230Vac only voltage switching power supply with an FLEX-ATX form-factor and
TFX 12V,+5V standby voltage,remote on/off .
)1. AC INPUT
1.1 AC input requirements
The input voltage, current, and frequency requirements for continuous
operation are stated below.
Table 1 AC Input Line Requirements
Parameter
Min
Vin
90
Vin Frequency
47
Iin(200,220W)
Iin(250W)
Nom.
100 -
240
3
1.3
3.5
1.5
Max Unit
264 VACrms
63
Hz
A
A
Parameter
Min
Vin
180
Vin Frequency
47
Iin(275W)
Nom.
200
240
2
Max Unit
264 VACrms
63
Hz
A
Power factor correction (PF)>0.95 at full load.
1.2 Inrush current regulation
The power supply must meet inrush requirements for any rated AC voltage, during turn on at any phase
of AC voltage, during a single cycle AC dropout condition, during repetitive ON/OFF cycling of AC,
and over the specified temperature range (Top). The peak inrush current shall be less than the ratings
of its critical components (including input fuse, bulk rectifiers, and surge limiting device).
)2. DC OUTPUT
2.1 DC voltage regulation
Parameter
Range
+3.3V
±5%
+5V
±5%
+12V1
±5%
+12V2
±5%
-12V
±10%
+5VSb
±5%
Min
+3.14
+4.75
+11.4
+11.4
-10.8
+4.75
Nom.
+3.3
+5.0
+12.0
+12.0
-12.0
+5.0
Max
+3.47
+5.25
+12.6
+12.6
-13.2
+5.25
1.At no load,3.3V output +/-5% regulation limits do not apply.
2.At +12V surge, regulation can go to +/-10%.
Unit
Volts
Volts
Volts
Volts
Volts
Volts
AUDIT:________李 復 新 _______CHECK:______________DESIGN:___
ENP7000 80Plus S SPEC REV: 4 0
1 OF 10
2009/2/9