EFRP-G753 Datasheet, PDF (1/2 Pages) List of Unclassifed Manufacturers – 1U 750W Redundant Power Module | |||
|
EFRP-S753
1U 750W Redundant Power Module
Features:
High Efficiencyâ§80%
0~50â Working Temperature
+12V and +5VSB Output
PMBus Monitoring and Control
General Specification
Âï Input Range: 92 to 264 VAC
Âï Power Factor: > 0.97 minimum
Âï Hold Up Time: 17ms @ 80% Load
Âï Short Circuit Protection
Âï Over Current Protection
Âï Over Voltage Protection
Âï No Load Operation
Âï MTBF >100,000 Hours@25â
Âï Operating Temperature: 0 to 40 â
Âï Operating Humidity: 20 to 90 %
Âï EMI/RFI: CE, FCC class B
Âï Safety: UL, TUV, CCC, CB, BSMI
Input and Output Characteristics
Input
Voltage
Frequency
100~240
47~63Hz
VAC
Current
10-6A
DC Output
Load
+12V +5VSB
Max.Load
62A
3.5A
Min.Load
0.8A
0.1A
Note: Total combined output shall not exceed 750W
Ripple and Noise
Output
Load Regulation
Line Regulation
Ripple & Noise
+12V
± 5%
± 1%
120mV
5Vsb
± 5%
± 1%
50mV
|
▷ |