English
Language : 

EFB0424VHD Datasheet, PDF (1/1 Pages) List of Unclassifed Manufacturers – Bearing Type Ball Bearings
EFB 40 x 40 x 20 MM SERIES
DIMENSIONS DRAWING
20.0 0.5
(0.787 0.020)
3.0 0.3
3.0 0.3
(0.118 0.012)
(0.118 0.012)
40.0 0.5
(1.575 0.020)
32.0 0.3
(1.260 0.012)
LABEL
* Bearing Type
Ball Bearings
* Material
Impeller & Frame : Plastic (UL 94V-0)
* Lead Wires :
UL 1007 AWG #24 Or Equivalent
Red Wire Positive (+)
Black Wire Negative (-)
* Weight : 33g (1.16 oz)
* Rib Type Only
10.0
(0.394)
330.0 10.0
(12.992 0.394)
P & Q CURVE (AT RATED VOLTAGE)
0.48 12.0
0.40 10.0
0.32 8.0
0.24 6.0
0.16 4.0
EFB0405/12/24XD
VH
HH
H
M
L
0.08 2.0
0
0
0 .08 .16 .24 .32 .40 (M3/MIN)
0 3.2 6.4 9.6 12.8 (CFM)
Air Flow
4- 3.5 0.2
(4- 0.138 0.008)
mm
UNIT:
(INCH)
MOUNTING PANEL CUTOUT
OUTLET SIDE
INLET SIDE
37.6
(1.480)
32.0
(1.260)
37.6
(1.480)
32.0
(1.260)
39.15.555)
(
4- 3.5
(4- 0.138)
39.15.555)
(
4- 3.5
(4- 0.138)
mm
UNIT:
(INCH)
MODEL
Rated
Voltage
PART NO. FUNCTION
EFB0405LD -R00 / -F00
EFB0412LD -R00 / -F00
EFB0424LD -R00 / -F00
EFB0405MD -R00 / -F00
EFB0412MD -R00 / -F00
EFB0424MD -R00 / -F00
EFB0405HD -R00 / -F00
EFB0412HD -R00 / -F00
EFB0424HD -R00 / -F00
EFB0405HHD -R00 / -F00
EFB0412HHD -R00 / -F00
EFB0424HHD -R00 / -F00
EFB0405VHD -R00 / -F00
EFB0412VHD -R00 / -F00
EFB0424VHD -R00 / -F00
VDC
5
12
24
5
12
24
5
12
24
5
12
24
5
12
24
Operating
Voltage
Range
VDC
4.5 to 5.5
7.0 to 13.8
14.0 to 27.6
4.5 to 5.5
7.0 to 13.8
14.0 to 27.6
4.5 to 5.5
7.0 to 13.8
14.0 to 27.6
4.5 to 5.5
7.0 to 13.8
14.0 to 27.6
4.5 to 5.5
7.0 to 13.8
14.0 to 27.6
Rated
Current
Amp
0.10
0.05
0.04
0.15
0.06
0.05
0.25
0.08
0.06
0.30
0.10
0.07
0.32
0.12
0.09
Rated
Input
Power
Watt
0.50
0.60
0.96
0.75
0.72
1.20
1.25
0.96
1.44
1.50
1.20
1.68
1.60
1.44
2.16
Speed
Maximum
Air Flow
R.P.M. m3 /min CFM
Maximum
Air Pressure
Noise
mmH2O IN H2O dB-A
5000 0.157 5.54 3.45 0.136 22.0
6300 0.203 7.17 5.54 0.218 24.0
7600 0.242 8.54 7.69 0.303 28.5
8200 0.267 9.43 9.00 0.354 30.5
9000 0.286 10.10 10.57 0.416 32.5
* Function type is optional.
* The max. air flow and the speed are measured in free air ; max. air pressure is measured at zero air flow.
* Noise is measured in anechoic chamber in free air, one meter from intake side.
* All readings are typical values at rated voltage.
* Specifications are subject to change without notice.
26
http://www.deltaww.com