English
Language : 

CTFCS20-24 Datasheet, PDF (1/3 Pages) List of Unclassifed Manufacturers – Transformers Chassis Mount
Transformers
Chassis Mount
Features:
• Single 230 V primary windings
• Double section metric bobbins
• Power : 6 to 200 VA, 50 / 60 Hz
• Temperature class : B (130°C)
• Dielectric strength : 3,750 Vrms
• Manufactured and tested in accordance with EN60950 and EN61558
Specifications:
Dimensions : Millimetres
Maximum winding temperature
Overall insulation rating
Flash test (isolation test)
Winding wire
Tape
Core
Finish
Dimension Table
: 55°C
: > 50 MΩ (at 500 V, 20°C)
: Primary / secondary / lamination 2.4 kVrms
: Polyurethane coated IEC317 grade 1
: 3M no 56 or 36M no 1350Y thermosetting
: 400 / 50
: Ultimeg 3.72 clear
Dimensions
VA
Rating
Reg%
A
B
C
D
E
F
G
H
I
J
K Weight (g)
6
24
55
68
37
45
36
170
12
16
45
390
74
90
50
60
-
-
-
-
-
-
20
12
52
530
50
9
94
106
65
79
53
985
Dimensions : Millimetres
www.element14.com
www.farnell.com
www.newark.com
www.cpc.co.uk
<Page 1>
20/12/11 V1.1