English
Language : 

AM-530 Datasheet, PDF (1/2 Pages) List of Unclassifed Manufacturers – True-rms Electrical True-rms Contractor Multimeter
www.Amprobe.com
AM-530
True-rms Electrical
Contractor Multimeter
AM-500 Digital Multimeter Series
The Amprobe AM-530 is the fully-featured multimeter of choice for the
professional electrical contractor. Measure and verify presence of voltage in
order to connect equipment or to perform repairs, run new wiring, check
continuity of electrical connections, identify blown fuses, troubleshoot motors
or check transformers. The AM-530 features true-rms sensing to accurately
measure voltage on systems affected by harmonics, a built in flashlight to
detect wire colors in the dark, a “third hand” probe holder and VolTect™
non-contact voltage detection.
• Voltage up to 750Vac and 1000Vdc, ac/dc
current, resistance, frequency, capacitance,
and temperature
• True-rms
• VolTect™ Non-contact voltage detection
• Audible continuity
• Diode test
• Data hold
• Max/min memory
• Relative zero mode
• Built-in test leads storage and “third hand”
test lead holder
• Auto and manual ranging
• Auto power off
• Low battery warning
• Safety rated: CAT III 600V
AM-530 Detailed Specifications
Specifications
Range
True-rms
AC Voltage
400 mV
4.000 / 40.00 / 400.0 / 600 V
DC Voltage
400mV
4.000 / 40.00 / 400.0 / 600 V
Resistance
400.0 Ohms
4.000 / 40.00 / 400.0 kOhms
4.000 / 40.00 MOhms
AC Current
400.0 / 4000 µA
40.00 / 400.0 mA
4.000 / 10.00 A
DC Current
400.0 / 4000 µA
40.00 / 400.0 mA
4.000 / 10.00 A
Frequency
10 Hz to 10 MHz
Capacitance
40.00 / 400.0 nF
4.000 / 40.00 / 400.0 / 4000 µF
Temperature
-40 °F to 1832 °F
-40 °C to 1000 °C
Number of
temperature inputs
For more detailed specifications see instruction manual.
Best Accuracy
Yes
±(1.0 % Rdg + 3 LSD) @ 45 Hz to 400 Hz, 4 V to 400 V ranges
±(0.8% Rdg + 1 LSD) @ 4 V to 400 V ranges
±(1.0% Rdg + 2 LSD) @ 4 kOhms to 400 kOhms ranges
±(1.2% Rdg + 3 LSD)
±(1.0% Rdg + 2 LSD)
±(0.1% Rdg + 4 LSD)
±(3.0% Rdg + 5 LSD) @ 400 nF to 40 µF ranges
°F: ±(1.8% rdg + 6 °F) @ >32 °F to 212 °F
°C: ±(1.2% rdg + 3 °C) @ >0 °C to 100 °C
Single Thermocouple
©2012 Amprobe Test Tools. All rights reserved.
For detailed specifications and ordering info go to www.amprobe.com
4137395 B