9LG0912P1H001 Datasheet, PDF (1/4 Pages) List of Unclassifed Manufacturers – High Air Flow Long Life Fan San Ace 92L | |||
|
92 9LG type
High Air Flow Long Life Fan
â Features
High Air Flow and High Static Pressure
The maximum air flow of the San Ace 92L 9LG type is
approximately 1.6 times and the maximum static pressure is
approximately 4 times higher than that of our conventional long
life fan.*
Long Life
The San Ace 92L 9LG type has an expected life of 180,000 hours
(approximately 20 years), making this fan ideal for equipment that
must operate without maintenance for extended periods.
*: Specification of Model No. 9LG0912P1H001. Our conventional long life fan is
92 x 92 x 25 mm âSan Ace 92Lâ, Model No. 9LG0912P4J001.
92Ã92Ã38mm
â Speciï¬cations
The following nos. have PWM controls, pulse sensors.
Model No.
Rated Voltage
Operating
Voltage Range
PWM
Duty Cycle
Rated Current Rated Input
Rated Speed
Max. Air Flow
MAX. Static Pressure
SPL
Operating
Temperature
Expected
Life
[V]
[V]
[%] (Note1, 2)
[A]
[W]
[min-1] [m3/min] [CFM] [Pa] [inchH2O] [dB(A)]
[â]
[h]
9LG0912P1H001
9LG0912P1F001
9LG0924P1H001
9LG0924P1F001
100
20
12
10.2 to 13.8
100
20
100
20
24
20.4 to 27.6
100
20
2.0
24.0
9,000
3.70 130.6 430
1.72
61
0.18
2.16
2,700
1.11 39.1 38.7
0.15
30
1.0
12.0
7,000
2.90 102.4 263
1.05
55
0.11
1.32
2,000
0.83 29.3 21.5
0.08
22
ï¼20 to ï¼70 180,000
0.9
21.6
9,000
3.70 130.6 430
1.72
61
0.08
1.92
2,700
1.11 39.1 38.7
0.15
30
0.5
12.0
7,000
2.90 102.4 263
1.05
55
0.06
1.44
2,000
0.83 29.3 21.5
0.08
22
Note1: PWM Frequency: 25 kHz
Note2: Fans do not rotate when PWM duty cycle is 0%.
Available options: Without Sensor Pulse Sensor
Please inquire as the availability of these functions depends on the model: Lock Sensor
â Common Speciï¬cations
⡠Material ・・・・・・・・・・・・・・・・・・・・・・・・・・ Frame: Aluminum, Impeller: Plastics (Flammability: UL94V-1)
â¡ Expected Life ・・・・・・・・・・・・・・・・・・・・・ Refer to speciï¬cations
(L10: Survival rate: 90% at 60 â, rated voltage, and continuously run in a free air state)
⡠Motor Protection System ・・・・・・・・・・ Current blocking function and reverse polarity protection
⡠Dielectric Strength ・・・・・・・・・・・・・・・・ 50 / 60 Hz, 500 VAC, 1 minute (between lead conductor and frame)
⡠Sound Pressure Level (SPL) ・・・・・・・・ Expressed as the value at 1 m from air inlet side
â¡ Operating Temperature ・・・・・・・・・・・・ Refer to speciï¬cations (Non-condensing)
â¡ Storage Temperature ・・・・・・・・・・・・・・ ï¼30 â to ï¼70 â (Non-condensing)
â¡ Lead Wire ・・・・・・・・・・・・・・・・・・・・・・・・ ï¼Redãâã¼BlackãSensor: Yellow Control: Brown
⡠Mass ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Approx. 270 g
|
▷ |