9GA0612P6G001 Datasheet, PDF (1/4 Pages) List of Unclassifed Manufacturers – DC Fan San Ace 60 | |||
|
DC Fan
60mm sq.
San Ace 60
15mm thick (GA type), 15mm thick
20mm thick (GA type), 20mm thick
25mm thick (S type), 25mm thick (G type)
25mm thick, 25mm thick (San Cooler)
38mm thick (GA type), 38mm thick (GV type)
38mm thick (G type)
Ë General Specifications
ɾMaterialÊÊÊÊÊÊÊÊFrame: Plastics (Flammability: UL94V-0),
Impeller: Plastics (Flammability: UL94V-0)
ɾExpected Life ÊÊÊÊÊRefer to specifications (L10: Survival rate: 90% at 60Ë ,
rated voltage, and continuously run in a free air state)
ɾLead Wire ÊÊÊÊÊÊÊá®red á®black Sensor yellow Control brown
ɾStorageTemperature Êʵ30Ë to Ê´70ËÊ¢Non-condensingÊ£
60 60 20 Ê·
Ê·
GA mm ʤMassɿ70gʥ
type
Low Power Consumption Fan
Ë Specifications The following nos. have PWM controls, pulse sensors, and ribs.
Model No.
9GA0612P6G001
9GA0612P6S001
9GA0624P6G001
9GA0624P6S001
Rated Voltage Operating Voltage Range PWM duty Rated Current Rated Input Rated Speed Max. Air Flow Max. Static Pressure SPL
ʦVʧ
ʦVʧ
cycleNote1)Ëʦ%ʧ ʦAʧ
ʦWʧ
ʦmin-1ʧ ʦm³/minʧ ʦCFMʧ ʦPaʧ ʦinchH²Oʧ ʦdB(A)ʧ
100
12 10.8 to 13.2
100
0.26 3.12
0.15 1.80
6,850 0.88 31.1 125 0.50 43
5,500 0.70 24.7 81 0.33 36
24 21.6 to 26.4 100
100
0.12 2.88
0.07 1.68
6,850 0.88 31.1 125 0.50 43
5,500 0.70 24.7 81 0.33 36
Operating Temperature Expected LifeNote2)
ʦËʧ
ʦhʧ
ʵ20 to ʴ70
40,000/60Ë
(70,000/40Ë)
Note 1: Fan does not rotate when PWM duty cycle is 0%.
Note 2: Expected life at 40Ë ambient is just reference value.
ËPWM FrequencyÉ¿25kHz
Model No.
9 G A 0 6 1 2 H 6 0 01
9 G A 0 6 1 2 M 6 0 01
9 G A 0 6 2 4 H 6 0 01
9 G A 0 6 2 4 M 6 0 01
The following nos. have pulse sensors and ribs.
Rated Voltage Operating Voltage Range Rated Current Rated Input Rated Speed
ʦVʧ
ʦVʧ
ʦAʧ
ʦWʧ
ʦmin-1ʧ
12
10.8 to 13.2
0.09
1.08
0.05 0.60
4,100
2,700
0.04 0.96
24
21.6 to 26.4
0.03
0.72
4,100
2,700
Max. Air Flow
ʦm³/minʧ ʦCFMʧ
0.52 18.4
0.34 12.0
0.52 18.4
0.34 12.0
Max. Static Pressure
ʦPaʧ ʦinchH²Oʧ
45 0.18
20 0.08
45 0.18
20 0.08
SPL
ʦdB(A)ʧ
29
18
29
18
Operating Temperature Expected Life
ʦËʧ
ʦhʧ
ʵ20 to ʴ70 60,000
ɾAvailable options: ˰ Without Sensor Pulse Sensor
ɾPlease inquire as the availability of these functions depend on the model. ˰ PWM Control
Ë DimensionsÊ¢Unit : mmÊ£(With PWM speed control functionɾWith pulse sensor)
4ʵÐ4.5ʶ0.3
Mà¤oà·un༻tinÝg Hole
ϦLeÊadÏ
Wઢire
AWG26
UL1007
+50
300 0
50ʶ0.3
60ʶ0.5
RotaÕ³tinà°¸g à¹DiÞ²rection
(10)
(4)
(4)
20ʶ0.5
Air à·©Floਧwà¥Dià¹reÞ²ction
55
|
▷ |