9A0612F401 Datasheet, PDF (1/2 Pages) List of Unclassifed Manufacturers – 15mm thick, 20mm thick, 25mm thick 25mm thick (San Cooler), 38mm thick (GV type) 38mm thick (G type)
DC Fan
60mm sq.
San Ace 60
15mm thick, 20mm thick, 25mm thick
25mm thick (San Cooler), 38mm thick (GV type)
38mm thick (G type)
˙ General Specifications With a pulse sensor Specifications for pulse sensors Refer to Page 261
ɾMaterialʜʜʜʜʜʜʜʜFrame: Plastics (Flammability: UL94V-0),
Impeller:Plastics (Flammability: UL94V-0)
ɾLife Expectancy ʜʜʜʜVaries for each modelʢL10:Survival rate:90% at 60ˆ ,
rated voltage, and continuously run in a free air stateʣ
ɾLead Wire ʜʜʜʜʜʜʜred black or blue Sensor yellow
ɾStorageTemperature ʜʵ30ˆ to ʴ70ˆʢNon-condensingʣ
60 60 25 ʷ ʷ mm ʤMassɿ80gʥ San Cooler
˙ Specifications The numbers in ( ) represent ribless models.
Model No.
9A0612G401(4011)
9A0612S401(4011)
9A0612H401(4011)
9A0612F401(4011)
9A0612M401(4011)
9A0624G401(4011)
9A0624S401(4011)
9A0624H401(4011)
9A0624F401(4011)
9A0624M401(4011)
Rated Voltage Operating Voltage Range Rated Current Rated Input
ʦVʧ
ʦVʧ
6 to 13.2
ʦAʧ
0.24
ʦWʧ
2.88
0.17 2.04
12
6 to 13.8 0.11 1.32
0.09 1.08
7 to 13.8 0.06 0.72
12 to 27.6 0.13 3.12
0.08 1.92
24 12 to 27.6 0.06 1.44
0.05 1.2
14 to 27.6 0.04 0.96
Rated Speed
ʦmin-1ʧ
5,600
4,600
3,800
3,200
2,600
5,600
4,600
3,800
3,200
2,600
Air Flow
ʦm³/minʧ ʦCFMʧ
0.78 27.6
0.65 23.0
0.53 18.7
0.44 15.5
0.36 12.7
0.78 27.6
0.65 23.0
0.53 18.7
0.44 15.5
0.36 12.7
Static Pressure SPL Operating Temperature Life Expectancy
ʦPaʧ ʦinchH²Oʧ ʦdB(A)ʧ
ʦˆʧ
87.3 0.351 39 ʵ10 to ʴ60
ʦhʧ
30,000
56.8 0.228 33
40.2 0.161 28
29.4 0.118 24 ʵ10 to ʴ70 40,000
19.6 0.079 20
87.3 0.351 39 ʵ10 to ʴ60 30,000
56.8 0.228 33
40.2 0.161
29.4 0.118
28
24
ʵ10 to ʴ70 40,000
19.6 0.079 20
Without Sensor Pulse Sensor Available in all models. Lock Sensor Please inquire as the availability of these functions depend on the model.
˙ DimensionsʢUnit : mmʣʢWith ribsʣ
+1
60 0
50ʶ0.3
4-П4.3ʶ0.3
Mऔo෇u༻nt݀ing Hole
LϦeaʔdυWઢire
AWG24
UL1007
+50
300 0
25ʶ0.5
Ê¢3Ê£
Ê¢3Ê£
Ê¢10Ê£
Rotatճinసg ํDi޲rection
Air෩Flਧowग़Dํir޲ection
˙ Reference dimension of
mounting holes and vent openingʢUnit : mmʣ
Inlet side, Outlet side
59
50ʶ0.3
4-П4.5
29.7