English
Language : 

80280302 Datasheet, PDF (1/2 Pages) List of Unclassifed Manufacturers – 4 x M5 trheaded holes on 40mm diameter, 4,5 mm thread depth
DCmind motor Brushless
Data sheet
80 280 302
Series
80 280 SMI21 CAN
4 x M5 trheaded holes on 40mm diameter, 4,5 mm thread depth
CAN connector - M12
micro-USB B connector
General characteristics
Power supply
Direct current voltage supply
Nominal voltage range
Max. current
Vdc
12 -> 48
A
14
Motor characteristics (1)
At no load
Max. output speed
Current at the max output speed (6)
Standby current
At nominal
Speed
Torque (4)
Output power
Current
Efficiency
At max. output power
Speed
Torque (4)
Output power
Current
Efficiency
At peak torque
Speed
Torque (4)
Output power
Current
Others
Life (2-3)
Rotor inertia
Thermal Resistance
Rotor poles
Cogging torque
Weight
Noise level
rpm
A
A
rpm
mNm
W
A
%
rpm
mNm
W
A
%
rpm
mNm
W
A
h
gcm²
°C/W
mNm
kg
dBA
12 Vdc 24 Vdc 48 Vdc
1 500
0,39
0,065
3 050
0,43
0,04
4 000
0,36
0,025
+-10%
1 180
650
80
8,9
75
2 380
565
141
8,0
73
3 910
460
190
4,8
83
+-10%
+-10%
970
1 000
102
13,8
61
1 900
1 000
199
14
59
3 630
1 000
380
10,2
78
+-10%
970
1 000
102
13,8
1 900
1 000
199
14
3 630
1 000
380
10,2
+-10%
+-10%
20 000
120
1,8
8
33
1,62
Connecting
Input / Output - M16 - 15 pins
Input 1 (digital)
Input 2 (digital)
Input 3 (digital)
Input 4 (digital)
Input 5 (analogic)
Input 6 (analogic)
0V
Output 1 (digital - PWM)
Output 2 (digital - PWM)
Output 3 (digital)
Output 4 (digital)
Not connected
Not connected
Power supply - M16 - 3 pins
Non connecté
+ 12Vcc -> + 48 Vcc
0V
Pin N°
1
2
3
4
5
6
7
8
9
10
11
12
A-B-C
Pin N°
1
2
3
Micro-USB B
Monitoring and setting
CAN - M12 - 5 pins
Not connected
Not connected
0V
CAN High
CAN Low
Pin N°
1
2
3
4
5
Crouzet Automatismes
2 rue du Docteur Abel BP59
26902 Valence CEDEX 9 France
Input/output connector - M16 - Hummel 7.003.985.101
Voltage suplly connector - M16 - Hummel 7.003.983.101
Earth: M6 threaded hole - 10mm thread depth
Drive
Type
Built-in drive
Internal encoder
Setting software on PC
CAN open standard and standalone capabilities
Control
Position - speed - torque
4 quadrants with regenerative energy
Type" Field Oriented Control"
SMI21 CAN
4096 points
DCmind Soft + CAN Open
Security
Low voltage
Short high voltage
Internal drive temperature protection (2)
Internal drive temperature protection (2)
Output cut-short
Input inverted
Vdc
<8
Vdc
> 85
°C
> 110
°C
< -40
Not protected
Not protected
Generic parameters
Motor for direct current supply
Output shaft with ball bearings
Max. Radial force
(12mm from front face)
Max. axial force(5)
Temperature range
CEI60068-2-1/2
Storage temperature
Dielectric
(1s/2mA/50Hz) CEI60335
Motor insulation
CEI60085
Salt spray
ISO9227
Degree of protection
CEI60529
(output shaft not included)
EMC
Electrostatic Discharge
CEI61000-4-2
Electrical fast transsient / burst test
CEI61000-4-4
Surge test
CEI61000-4-5
Radiated emission
EN55022
Approvals
ROHS
2011/65/CE
CE
CAN Open
CIA 301 - DSP 402
Communication
USB (Setting, monitoring)
CAN open: adress - node ID (plant output)
CAN open: baud rate (plant output)
N
N
°C
°C
Vac
class
severity
40
20
-30 -> +70
-40 -> +80
1 000
E
2
IP65
level
3
level
3
level
1
class
A
Micro-USB B
0x0A
kbaud
1000
Brake
Type
Power OFF brake
Voltage supply
Nominal holding torque
Input power
Static
Vdc
Nm
W
24 +- 10%
0,5
6,6
Notes
Values without tolerences, are average production values.
EDS file and "manual of use" and "security manual" and "motor manual" are available in English at
www.crouzet-motors.com and also in the "starter kit"
Motor not protected in case of reversed power voltage
(1) Cold motor, 20 ° C ambient temperature, full speed
(2) With max.torque (limit tab ) lower than peack torque
(3) Continuously rated torque, zero radial and axial loads
(4) Max torque for continuous operation at 20 ° C, decrease this value for higher ambient
temperature
(5) Pinion or pulley fitting are done at the Crouzet factory, before final assembly.
Specifications subject to change without notice. Updated June, 02 2016
www.crouzet-motors.com