English
Language : 

4300FE Datasheet, PDF (1/2 Pages) List of Unclassifed Manufacturers – Commercial applications shielded
TECHNICAL DATA SHEET
concept
4300FE NON-PAIRED
APPLICATION
Commercial applications shielded
CONSTRUCTION
code
version 1
date 2004-04-20
page 1/2
1. Conductor
Diameter of conductor
Material
1.22mm (AWG18)
stranded bare copper (7xAWG26)
2. Insulation
Material
Diameter over insulation
Wallthickness
PE
1.72 ± 0.05 mm
0.25 mm
3. Overall Cabling
Colour code
4. Outer shield
Shield
Shield Material
Shield Thickness Alu
Shield coverage
Drainwire
black – red
Beldfoil®)
Aluminium / Polyester tape
9 µm
100%
AWG20 (7xAWG28) tinned Cu
4. Sheath
Material
Colour
Nominal thickness of sheath
Diameter over sheath
FRNC
Grey
0.38 mm
4.2 ± 0.30 mm
REQUIREMENTS AND TEST METHODS
Electrical:
Nominal resistance conductor
Nominal resistance shield
Nom. capacitance conductor to conductor @ 1kHz
Nom. capacitance cond. to shield + other cond. @ 1kHz
Testvoltage conductor-conductor
Testvoltage conductor-screen
Voltage rating
Maximum continues current per conductor @ 25 °C
21.3 Ω/km
23.6 Ω/km
125 pF/m
224 pF/m
2500 VDC, 3 seconds
2500 VDC, 3 seconds
300 V RMS
3.5 A per conductor @ 25 ˚C
© Belden Wire & Cable B.V.
All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner