English
Language : 

3076F Datasheet, PDF (1/3 Pages) List of Unclassifed Manufacturers – 1 pair 18 AWG stranded (7x26) tinned copper conductors, polyolefin insulation
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
3076F Multi-Conductor - DataBus® ISA/SP-50 FOUNDATION Fieldbus or PROFIBUS Cable
For more Information
please call
1-800-Belden1
General Description:
1 pair 18 AWG stranded (7x26) tinned copper conductors, polyolefin insulation, polyolefin filler, Beldfoil®
shield (100% coverage), tinned copper drain wire, binder, PVC jacket. Fieldbus Foundation Registered
Product.
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material Dia. (mm)
1
18 7x26
TC - Tinned Copper 1.168
Total Number of Conductors:
2
Insulation
Insulation Material:
Insulation Material
PO - Polyolefin
Outer Shield
Outer Shield Material:
Outer Shield Trade Name Type Outer Shield Material
Coverage (%)
Beldfoil®
Tape Aluminum Foil-Polyester Tape 100
Outer Shield Drain Wire AWG:
AWG Stranding Drain Wire Conductor Material
20 7x28
TC - Tinned Copper
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
PVC - Polyvinyl Chloride
Outer Jacket Diameter:
Nom. Dia. (mm)
7.112
Overall Cable
Overall Cabling Fillers:
Overall Cabling Lay Length & Direction:
Length (mm) Twists (twist/m)
57.150
17.3893
Polypropylene
Mechanical Characteristics (Overall)
Operating Temperature Range:
UL Temperature Rating:
Bulk Cable Weight:
Max. Recommended Pulling Tension:
Min. Bend Radius/Minor Axis:
-40°C To +105°C
105°C
56.552 Kg/Km
266.892 N
63.500 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification:
CM, CMX-Outdoor, PLTC-ER
NEC Articles:
725, 727, 800
CEC/C(UL) Specification:
CMG
EU Directive 2011/65/EU (ROHS II):
Yes
EU CE Mark:
Yes
EU Directive 2000/53/EC (ELV):
Yes
Page 1 of 3
01-09-2015