English
Language : 

2PT100-KN1517 Datasheet, PDF (1/1 Pages) List of Unclassifed Manufacturers – CERAMIC WIRE WOUND PRTDS ARE SUITABLE
2 Pt100 KN 1517
The KN Series Ceramic Wire Wound PRTDs are suitable for
general applications requiring temperature stability. The
dual sensor can be used in redundancy systems.
1
Applications: Industrial resistance thermometers, especially
2
in chemical, power generation plants and analytical
equipment.
Construction: Two separate platinum coils are embedded
and sealed inside a high purity aluminum oxide ceramic
body. Lead wires are shear force resistant and assure proper
connection to extension leads and cables.
Models
Description
Tolerance Order No.
IEC 60751
Dimensions
mm
Response time
Self Heating
0°C (K/mW) Water current Air stream
V=0.4m/s V=3m/s
L
D
d
l1
l2
t 0.5
t 0.9
t t 0.5
0.9
2Pt100 KN 1517
W0.3
W0.15
W0.1
32.206.157
32.206.158
32.206.159
+2
15 - 0
1.7±0.15 0.20±0.01 11.0±0.5 10.0±0.5
To be released soon
Technical Specification
Nominal resistance: 100 Ohm @ 0 °C
Temperature range: W0.3 (Class B) = -196 to +660 °C
Temperature
coefficient:
W0.15 (Class A) = -196 to +600 °C
(Heraeus exceeds IEC 60751: -100 to +450 °C)
W0.1 (Class 1/3) = -100 to +350 °C
Tc = 3850 ppm/K
Leads:
Palladium-gold alloy
Insulation resistance
after assembly:
> 100 MOhm @ 25 °C
Measuring current: 1 mA
Tolerance class:
- According to IEC 60751:2008
- Other standards and narrower
tolerances are available on request
Temperature stability: Excellent long-term stability
Also available:
- Platinum-gold alloy
- Different temperature coefficients
(3916 ppm/K - old JIS)
- Extension leads
The measuring point is located at 8 mm from the end of the sensor body
Heraeus Sensor Technology USA
1901 Route 130
North Brunswick, NJ 08902
Phone 732-940-4400 Fax 732-940-4445
Email info.hst-us@heraeus.com
www.hst-us.com
Status: HSTUSA 10/09