English
Language : 

2712 Datasheet, PDF (1/2 Pages) KR Electronics, Inc. – Bandpass Filter
Data Sheet
True RMS AC + DC Tool Kit® DMM
Model 2712
TRUE RMS
Auto/ Manual Ranging
Select between Auto or
Manual ranging
The 2712 is a full featured auto ranging true RMS DMM that combines
performance, value and functionality. The 40000 count LCD has a green back
light that allows the meter to be used in dimly lit environments. The 2712 can
measure resistance values up to 40 Mohm and capacitance to 40 uF. With the
auto power off feature you won’t have to worry about accidental battery
consumption. Value-packed features make this meter a must in every "Tool Kit®".
Specifications
2712
model
DC Volts
Ranges
400 mV, 4 V, 40 V, 400 V, 1000 V
Resolution
0.01 mV, 1 mV, 10 mV, 100 mV, 1 V
Accuracy
400 mV range: ±(0.15 % rdg + 10 dgts)
Input Impedance
4 V to 1000 V ranges: ±(0.1 % rdg + 5 dgts)
400 mV: >3 MΩ; 4 V to 1000 V: 2.3 MΩ
Overload Protection
1000 VDC or 750 VACrms
AC Volts (True RMS) (45 Hz-1 kHz)
Ranges
400 mv, 4 V, 40 V, 400 V, 750 V
Resolution
0.01 mV, 1 mV, 10 mV, 100 mV, 1 V
Accuracy
400 mV to 400 V ranges: ±(1.2% rdg + 20dgts) 45 ~ 60 Hz
4 V range: ±(1.5% rdg + 20 dgts) 60 ~ 500 Hz
40 V to 400 V ranges: ±(1.5% rdg + 20dgts) 60 ~ 1 kHz
750 V range: ±(2.0% rdg + 20 dgts) 45 ~ 500 Hz
AC + DC Volts (True RMS) (45 Hz-1 kHz)
Ranges
400 mv, 4 V, 40 V, 400 V, 750 V
Resolution
0.01 mV, 1 mV, 10 mV, 100 mV, 1 V
Accuracy
400 mV to 400 V ranges: ±(1.5% rdg + 20dgts) 45 ~ 60 Hz
4 V range: ±(2.0% rdg + 20 dgts) 60 ~ 500 Hz
40 V to 400 V ranges: ±(2.0% rdg + 20dgts) 60 ~ 1 kHz
750 V range: ±(2.0% rdg + 20 dgts) 45 ~ 500 Hz
Crest Factor
≤3
AC coupled True RMS
Input Impedance
Specified from 10% to 100% of range
400 mV: >3 MΩ; 4 V to 750 V: 2.3 MΩ
Overload Protection
1000 VDC or 750 VACrms
DC Current
Ranges
40 mA, 400 mA, 10 A
Resolution
1 uA, 10 uA, 10 mA
Accuracy
40 mA to 400 mA ranges: ±(0.5% rdg + 10 dgts)
10 A range: ±(2.0% rdg + 10 dgts)
Input Protection
0.5 A/500 V & 10 A/500 V fast blow ceramic fuses
10A Input
10 A for 60 sec max. followed by a 10 minute cooling period
Voltage Burden
40 mA, 10 A ranges: 0.2V; 400 mA range: 1 V
AC Current (True RMS) (50 Hz-1 kHz)
Ranges
40 mA, 400 mA, 10 A
Resolution
1 uA, 10 uA, 10 mA
Accuracy
40 mA to 400 mA ranges: ±(2.0% rdg + 30 dgts)
10 A range: ±(2.5% rdg + 30 dgts)
Crest Factor
≤3
AC coupled True RMS
Specified from 10% to 100% of range
Voltage Burden
40 mA, 10 A ranges: 0.2V; 400 mA range: 1 V
Input Protection
0.5 A/500 V & 10 A/500 V fast blow ceramic fuses
10A Input
10 A for 60 sec max. followed by a 10 minute cooling period
Resistance
Ranges
400 Ω, 4 kΩ, 40 kΩ, 400 kΩ, 4 MΩ, 40 MΩ
Resolution
0.01 Ω, 0.1 Ω, 1.0 Ω, 10 Ω, 1 kΩ, 10 kΩ
Accuracy
400 Ω range: ±(0.3% rdg + 15dgts)
4 kΩ to 400 kΩ ranges: ±(0.3% rdg + 5dgts)
4 MΩ range: ±(0.5% rdg +10 dgts)
40 MΩ range: ±(1.5% rdg + 20 dgts)
Open Circuit Voltage (typical) 1.2 Vdc (2.5 Vdc on 400 Ω range)
Overload Protection
500 VDC/ACrms
Capacitance
Ranges
4 nF, 40 nF, 400 nF, 4 uF, 40 uF
Resolution
1 pF, 10 pF, 100 pF, 1 nF, 10 nF
Accuracy
4 nF range: ±(3.0% rdg + 20 dgts)
40 nF to 400 nF ranges: ±(3.0% rdg + 5 dgts)
4 uF to 20 uF ±(3.0% rdg + 5 dgts)
20 uF to 40 uF ±(5.0% rdg + 5 dgts)
Overload Protection
500 VDC/ACrms
Frequency
Ranges
100 Hz, 1 kHz, 10 kHz, 100 kHz, 500 kHz
Resolution
0.01 Hz, 0.1 Hz, 1 Hz, 10 Hz, 100 Hz
Accuracy
±(0.1 % rdg + 10 dgts)
Sensitivity
5 Hz-100 kHz: >500 mVrms, 100 kHz-500 kHz: >1.5 Vrms
Minimum Pulse Width
>2 us
Duty Cycle Limits
>30 % and <70 %
Overload Protection
500 VDC/AC rms
Diode Test
Test Current
0.8 mA (typical)
Resolution
0.1 mV
Accuracy
±(1.5 % rdg + 10 dgts)
Open Circuit Voltage
3.0 VDC (typical)
Overload Protection
500 VDC/ACrms
Continuity
Audible Indication
Less than 40 Ω
Response Time
500 ms
Overload Protection
500 VDC/ACrms
General
Display
4 3/4 digit, 40000 count LCD
Analog Bargraph
40 segments with measurements of 20 times per second
Polarity
Automatic, positive implied, negative polarity indication
Overrange
MSD (Most Significant Digit) Blinks
Low Battery Indication
Battery symbol will display when battery voltage drops below
operating levels
Measurement Rate
2 times per second
Auto Power Off
Approximately 30 minutes
Operating Environment
0ºC to 50ºC at <70 % relative humidity
Storage Environment
-20ºC to 60ºC at 0 to 80 % relative humidity
Accuracies
Stated accuracy at 23ºC +5ºC at <75 % relative humidity
Temperature Coefficient 0.1 x (specified accuracy) per ºC. (ºC to 18ºC, 28ºC to 50ºC)
Power
Single standard 9 volt battery, NEDA 1604, JIS 006P, IEC 6F22
Battery Life
150 hours typical
Dimensions
165 mm (H) x 78 mm (W) x 42.5 mm (D)
Weight
Approximately 10 oz. (285 g) with battery and hanger
Three-Year Warranty
Supplied Accessories: User manual, one set of test leads, one spare fuse, and 9V battery (installed)
Technical data subject to change
© B&K Precision Corp. 2013
Page 1 of 2
www.bk precision.com
Tel.: 714.921.9095