English
Language : 

2706B Datasheet, PDF (1/2 Pages) List of Unclassifed Manufacturers – Auto power off
Data Sheet
Manual Ranging Tool Kit® DMM with Temperature
Model 2706B
LCD back light
Ultra bright blue LCD back
light for low ambient light
measurements
The 2706B is a versatile manual-ranging DMM with temperature measurement.
The 2000 count LCD has a bright blue back light that allows the meter to be
used in dimly lit environments. With the auto-power-off feature you won’t have to
worry about accidental battery consumption. Value-packed features make this
meter a must in every "Tool Kit®".
Features
I Auto power off
I DC voltage to 1000 V
I Resistance to 20 MΩ
I One-handed operation
I Magnetic hanger
I Bright blue LCD backlight
I AC voltage to 750 V
I Capacitance to 20 mF
I Continuity test
I Diode test
Specifications
2706B
model
DC Volts
Ranges
Resolution
Accuracy
Input Impedance
Overload Protection
AC Volts (50 Hz-500 Hz)
Ranges
Resolution
Accuracy
Input Impedance
Overload Protection
200 mV, 2000 mV, 20 V, 200 V 1000 V
0.1 mV, 1 mV, 10 mV, 100 mV, 1 V
±(0.5 % rdg + 1 dgts)
10 MΩ
1000 VDC or 750 VACrms*
200 mV, 2000 mV, 20 V, 200 V 750 V
0.1 mV, 1 mV, 10 mV, 100 mV, 1 V
200 mV & 20 V ranges: ±(1.2 % rdg + 5 dgts)
200 V & 750 V ranges: ±(2.0 % rdg + 5 dgts)
10 MΩ
1000 VDC or 750 VACrms*
DC Current
Ranges
200 uA, 20 mA, 200 mA
Resolution
0.1 uA, 10 uA, 100 uA
Accuracy
±(1.0% rdg + 1 dgts)
Input Protection
0.25 A/500 V fast blow ceramic fuse
AC Current (50 Hz-500 Hz)
Ranges
200 uA, 20 mA, 200 mA
Resolution
0.1 uA, 10 uA, 100 uA
Accuracy
±(1.5% rdg + 5 dgts)
Input Protection
0.25 A/500 V fast blow ceramic fuse
Resistance
Ranges
200 Ω, 2 kΩ, 200 kΩ, 20 MΩ
Resolution
0.1 Ω, 1.0 Ω, 100 Ω, 10 kΩ,
Accuracy
200 Ω to 200 kΩ ranges: ±(1.0 % rdg + 4 dgts)
20MΩ range: ±(2.0 % rdg + 4 dgts)
Open Circuit Voltage (typical) 0.3 VDC (3.0 VDC on 200 Ω)
Overload Protection
500 VDC/ACrms
Capacitance
Ranges
200 uF, 2 mF, 20 mF
Resolution
0.1 uF, 1.0 uF, 10 uF
Accuracy
±(4 % rdg + 10 dgts)
Overload Protection
0.25 A/500 V fast blow ceramic fuse
Frequency
Ranges
10 Hz to 40 kHz
Resolution
1 Hz
Accuracy
±(0.1 % rdg + 3 dgts)
Sensitivity
3.5 Vrms minimum
Overload Protection
500 VDC/AC rms
Diode Test
Test Current
1.0 mA (typical)
Resolution
10 mV
Accuracy
±(1.5 % rdg + 3 dgts)
Open Circuit Voltage
3.0 VDC (typical)
Overload Protection
500 VDC/ACrms
Continuity
Audible Indication
Less than 100 Ω
Response Time
100 ms
Overload Protection
500 VDC/ACrms
Temperature
Ranges
-35ºC to 750ºC, -30ºF to 1400ºF
Resolution
0.1ºC, 0.1ºF
Accuracy
0ºC to 400ºC ±(1.0 % rdg + 1ºC)
-35ºC to 0ºC, 400ºC to 750ºC ±(3.0 % rdg + 3ºC)
-4ºF to 750ºF ±(1.0 % rdg + 2ºF)
-30ºF to -4ºF, 750ºF to 1400ºF ±(3.0 % rdg + 6ºF)
Sensor Type
K-type thermocouple
Overload Protection
60 VDC or 30 VACrms
General
Display
3 1/2 digit, 2000 count LCD
Polarity
Automatic, positive implied, negative polarity indication
Overrange
OL or -OL is displayed
Low Battery Indication
Battery symbol will display when battery voltage drops below
operating levels
Measurement Rate
2.5 times per second
Auto Power Off
Approximately 25 minutes
Operating Environment
0ºC to 50ºC at <70 % relative humidity
Storage Environment
-20ºC to 60ºC at 0 to 80 % relative humidity
Accuracies
Stated accuracy at 23ºC +5ºC at <75 % relative humidity
Temperature Coefficient 0.1 x (specified accuracy) per ºC. (ºC to 18ºC, 28ºC to 50ºC)
Power
Single standard 9 volt battery, NEDA 1604, JIS 006P, IEC 6F22
Battery Life
150 hours typical
Dimensions
165 mm (H) x 78 mm (W) x 42.5 mm (D)
Weight
Approximately 10 oz. (285 g) with battery and hanger
Three-Year Warranty
Supplied Accessories: User manual, one set of test leads, one spare fuse, 9V battery (installed),
and one K-type thermocouple
*= 600 VDC/Acrms for 15 seconds on 200 mV range
Technical data subject to change
© B&K Precision Corp. 2013
Page 1 of 2
www.bk precision.com
Tel.: 714.921.9095