English
Language : 

2704C Datasheet, PDF (1/2 Pages) List of Unclassifed Manufacturers – Magnetic hanger
Data Sheet
Manual Ranging Tool Kit® DMM with Transistor Test
Model 2704C
hFE Transist or Test
Measures common-
emitter gain.
The 2704C has all of the functionality for basic DMM applications including
some high end features you might not expect. The 2000 count LCD can display
resistance values up to 2 GΩ, capacitance to 20 uF or a transistors
common-emitter gain value up to 1000. Value-packed features make this meter a
must in every "Tool Kit®".
Features
I Magnetic hanger
I AC voltage to 750 V
I DC voltage to 1000 V
I Resistance to 2000 MΩ
I Capacitance to 20 uF
I Continuity test
I Diode test
I Logic test
I hFE Transistor test
I One-handed operation
I Measures up to 10 A (AC & DC)
Specifications
2704C
model
DC Volts
Ranges
200 mV, 2 V, 20 V, 200 V, 1000V
Resolution
0.1 mV, 1 mV, 10 mV, 100 mV, 1 V
Accuracy
±(0.8 % rdg + 1 dgts)
Input Impedance
10 MΩ
Overload Protection
1000 VDC or 750 VACrms*
AC Volts (50 Hz-500 Hz)
Ranges
200 mV, 2 V, 20 V, 200 V, 750V
Resolution
0.1 mV, 1 mV, 10 mV, 100 mV, 1 V
Accuracy
200 mV & 20 V ranges: ±(1.5 % rdg + 5 dgts)
200 V & 750 V ranges: ±(2.0 % rdg + 5 dgts)
Input Impedance
10 MΩ
Overload Protection
1000 VDC or 750 VACrms*
DC Current
Ranges
20 mA, 200 mA, 10 A
Resolution
10 uA, 100 uA, 10 mA
Accuracy
20 mA to 200 mA ranges: ±(1.0 % rdg + 1 dgts)
10 A range: ±(3.0 % rdg + 3 dgts)
Input Protection
0.5 A/500 V & 10 A/600 V fast blow ceramic fuses
10A Input
10 A for 60 sec max. followed by a 10 minute cooling period
AC Current (50 Hz-500 Hz)
Ranges
20 mA, 200 mA, 10 A
Resolution
10 uA, 100 uA, 10 mA
Accuracy
20 mA to 200 mA ranges: ±(2.0 % rdg + 5 dgts)
10 A range: ±(3.0 % rdg + 5 dgts)
Input Protection
0.5 A/500 V & 10 A/600 V fast blow ceramic fuses
10A Input
10 A for 60 sec max. followed by a 10 minute cooling period
Resistance
Ranges
200 Ω, 2 kΩ, 200 kΩ, 20 MΩ, 2000 MΩ
Resolution
0.1 Ω, 1.0 Ω, 100 Ω, 10 kΩ, 1 MΩ
Accuracy
200 Ω to 200 kΩ ranges: ±(1.0 % rdg + 4 dgts)
20 MΩ range: ±(2.0 % rdg + 4 dgts)
2000 MΩ range: ±(5.0 % rdg + 10 dgts)
Open Circuit Voltage (typical) 0.3 VDC (3.0 VDC on 200 Ω, 2000 MΩ range)
Overload Protection
500 VDC/ACrms
Capacitance
Ranges
2 nF , 20 nF, 200 nF, 2.0 uF, 20 uF
Resolution
1 pF, 10 pF, 100 pF, 1 nF, 10 nF
Accuracy
±(4 % rdg + 10 dgts)
Overload Protection
Discharge capacitor before connecting
Frequency
Ranges
2 kHz, 20 kHz, 200 kHz, 2 MHz, 20 MHz
Resolution
1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz
Accuracy
±(0.1 % rdg + 3 dgts)
Sensitivity
2.0 Vrms minimum
Minimum Pulse Width
>25 ns
Duty Cycle Limits
>30 % and <70 %
Overload Protection
500 VDC/AC rms
Diode Test
Test Current
1.0 mA (typical)
Resolution
10 mV
Accuracy
±(1.5 % rdg + 3 dgts)
Open Circuit Voltage
3.0 VDC (typical)
Overload Protection
500 VDC/ACrms
Continuity
Audible Indication
Less than 100 Ω
Response Time
100 ms
Overload Protection
500 VDC/ACrms
Transistor hFE
Range
0 to 1000
Base Current
Approximately 10 uADC (VCE = 3.0 VDC)
Logic Test
Threshold
Logic Hi (2.8 V ±0.8 V) / Logic Lo (0.8 V ±0.5 V)
Indication
40 msec beep at logic Lo
Overload Protection
500 VDC/AC rms
General
Display
3 1/2 digit, 2000 count LCD
Polarity
Automatic, positive implied, negative polarity indication
Overrange
OL or -OL is displayed
Low Battery Indication
Battery symbol will display when battery voltage drops below
operating levels
Measurement Rate
2.5 times per second
Operating Environment
0ºC to 50ºC at <70 % relative humidity
Storage Environment
-20ºC to 60ºC at 0 to 80 % relative humidity
Accuracies
Stated accuracy at 23ºC +5ºC at <75 % relative humidity
Temperature Coefficient 0.1 x (specified accuracy) per ºC. (ºC to 18ºC, 28ºC to 50ºC)
Power
Single standard 9 volt battery, NEDA 1604, JIS 006P, IEC 6F22
Battery Life
150 hours typical
Dimensions
165 mm (H) x 78 mm (W) x 42.5 mm (D)
Weight
Approximately 10 oz. (285 g) with battery and hanger
Three-Year Warranty
Supplied Accessories: User manual, one set of test leads, one spare fuse, and 9V battery (installed)
*= 600 VDC/Acrms for 15 seconds on 200 mV range
Technical data subject to change
© B&K Precision Corp. 2013
Page 1 of 2
www.bk precision.com