English
Language : 

26M048B1B Datasheet, PDF (1/1 Pages) List of Unclassifed Manufacturers – How to select your CanStack motor
How to select your
CanStack motor
Selection Criteria
• The Torque – Speed Curves are essential for selecting the right motor and control drive method for a specific application.
• Define your application load – speed required, load inertia, torque and accuracy needed.
• If the application requires no acceleration, then use the pull out torque.
• If the load is inertial (acceleration is required), it is advisable to use pull in torque.
• Motor temperature rise is important – so ambient temperature and duty cycle are important selection factors
• It is advisable to use 1.5 to 2 times the margin over the maximum torque required.
• Choosing the correct drive is important – for example micro-stepping drives will provide quieter operation.
• Our engineering team is capable of designing a special coil with resistance and inductances to suit your needs.
• Remember – if it is not in the catalog – it does not mean that we cannot provide a solution for you - Portescap may still be
able to design a product for your needs as our team can draw from a wealth of customized designs created over the past
40 years.
CANSTACK Motor Designation
26M048D2B
26
M
048
D
2
B
Motor
Diameter
(mm)
15
20
26
35
42
55
Rotor Dia
S = Small
M = Medium
L = Large
Steps per
Rev
020: 20 ppr
024: 24 ppr
048: 48 ppr
100: 100 ppr
Magnet Type
B = Ferrite
C = He Ferrite
D = Neodymium
Voltage
1=5V
2 = 12 V
Coil
U = Unipolar
B = Bipolar