English
Language : 

1PT100-KN3045 Datasheet, PDF (1/1 Pages) List of Unclassifed Manufacturers – CERAMIC WIRE WOUND PRTDS ARE SUITABLE
1 Pt100 KN 3045
The KN Series Ceramic Wire Wound PRTDs are suitable for
general applications requiring temperature stability.
Applications: Industrial resistance thermometers, especially
in chemical, power generation plants and analytical
equipment.
Construction: A platinum coil is sealed inside a high purity
aluminum oxide ceramic body. Lead wires are shear force
resistant and assure proper connection to extension leads
and cables.
Models
Description
Tolerance Order No.
IEC 60751
L
Dimensions
mm
D
d
Response time
Self Heating
0°C (K/mW) Water current Air stream
V=0.4m/s V=3m/s
l
t 0.5
t 0.9
t t 0.5
0.9
1Pt100 KN 3045
W0.3
32.206.530
+3
W0.15
32.206.533
30- 0
4.5±0.15 0.27±0.01 10.0±0.5
W0.1
32.206.548
0.01
0.4 1.4 26.0 90.0
Technical Specification
Nominal resistance: 100 Ohm @ 0 °C
Temperature range: W0.3 (Class B) = -196 to +660 °C
Temperature
coefficient:
W0.15 (Class A) = -196 to +600 °C
(Heraeus exceeds IEC 60751: -100 to +450 °C)
W0.1 (Class 1/3 B) = -100 to +350 °C
Tc = 3850 ppm/K
Leads:
Palladium-gold alloy
Insulation resistance
after assembly:
> 100 MOhm @ 25 °C
Measuring current:
Tolerance class:
1 mA
- According to IEC 60751:2008
- Other standards and narrower
tolerances are available on request
Temperature stability: Excellent long-term stability
Also available:
- Platinum-gold alloy
- Different temperature coefficients
(3916 ppm/K - old JIS)
- Extension leads
- Two separated coils can be embedded
in one ceramic body
The measuring point is located at 8 mm from the end of the sensor body
Heraeus Sensor Technology USA
1901 Route 130
North Brunswick, NJ 08902
Phone 732-940-4400 Fax 732-940-4445
Email info.hst-us@heraeus.com
www.hst-us.com
Status: HSTUSA 10/09