English
Language : 

19218 Datasheet, PDF (1/4 Pages) List of Unclassifed Manufacturers – Workstation Continuous Mini Monitor Operation, Installation and Maintenance
  TECHNICAL BULLETIN TB-3050 
Jewel® Workstation Continuous Mini Monitor
Operation, Installation and Maintenance
Made in the
United States of America
A broken wrist strap may expose products to ESD
over an entire shift if it is checked only at shift change
with wrist strap checker.” (ESD TR 12-01 Section 4.2
Selection Considerations)
Figure 1. Desco 19218 Jewel® Workstation Continuous
Mini Monitor
Description
The Jewel® Workstation Continuous Mini Monitor
independently monitors the operator and the
worksurface. The instant an operator’s wrist strap or
cord fails, the monitor will issue audible and visual
alarms alerting the user of the problem. In the same
manner, the unit also confirms that a path to ground
of less than 500 megohms exists from the ESD
worksurface.
The Jewel® Workstation Continuous Monitor is a Single
Conductor Impedance Sensing Continuous Monitor
which per ESD Handbook TR20.20 section 5.3.9.2.1 “a
small AC voltage is used in a detection circuit designed
to eliminate false alarms and adjustment. They use the
phase difference between current and voltage to detect
changes in impedance of the grounding cord, wristband
and person. No adjustments are required.”
Per ESD Handbook ESD TR20.20 section 5.3.2.4.4,
“Typical test programs recommend that wrist straps that
are used daily should be tested daily. However, if the
products that are being produced are of such value that
knowledge of a continuous, reliable ground is needed,
and then continuous monioring should be considered or
even required.”
Advantages Of Continuous Monitoring
Over Periodic Testing
“When considering constant [or continuous] monitors,
the equipment cost including the wrist strap,
maintenance and training cost, labor time for performing
wrist strap tests, and the potential failures due to non-
functional wrist straps should be considered.
The Jewel® Workstation Continuous Monitor eliminates
the need for periodic wrist strap tests and logging.
Continuous monitoring is superior to periodic or pulsed
testing, and can save a significant amount of money
in testing costs and rejected product. Periodic testing
detects failures after ESD susceptible products way
have been manufactured. The costs of dealing with
the resulting catastrophic or latent defects can be
considerable. Jewel® Workstation Continuous Mini
Monitors eliminate the need for operaters to test wrist
straps and log the results; by their function, these
monitors satisfy the ISO 9000 and ANSI/ESD S20.20
test logging. ANSI/ESD S20.20 Section 6.2.2.2
Personnel Grounding Guidance states “A log should be
maintained which verifies that personnel have tested
their personal grounding devices.” Per ANSI/ESD-S1.1
Annex A Section 6.1.3 “Daily (wrist strap system) testing
may be omitted if constant monitoring is used.” Per
ANSI/ESD-S1.1 Annex A Frequency of Functional
Testing, “The wrist strap system should be tested daily
to ensure proper electrical value. Daily testing may be
omitted if constant monitoring is used.”
Park Snap
The audible alarm is designed to alert both operator and
supervisor. The Park Snap feature provides a means
for an operator to disconnect when normally leaving
the work area, without the audible alarm sounding, and
wrist cord storage (visual red LED will illuminate). When
the operator touches the Park Snap, the audible alarm
is disabled for about 8-10 seconds. The operator can
remove the wrist strap cord and attach socket of the
cord to Park Snap for storage. The coil cord may also
be removed from the jack on the Jewel® monitor without
the alarm sounding. Once the coil cord is in the park
position, the operator ground status light will remain red.
Wave Distortion Detection Technology
Provides True 100% Continuous Monitoring
Wave distortion impedance circuitry monitors current /
voltage phase shifts and provides true 100% continuous
monitoring. Electrical current will lead voltage at various
points due to the combinations of resistance and
capacitive reactance. By monitoring these “distortions”
or phase shifts, the Jewel® Workstation Continuous Mini
Monitor will reliably determine if the circuit is complete.
DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178
DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Website: Desco.com
TB-3050 Page 1 of 4 April 2013
© 2013 DESCO INDUSTRIES, INC.
Employee Owned