General Description:
RG-6/U type, 18 AWG solid .040" bare copper conductor, plenum, foam FEP insulation, Duofoil® + tinned
copper braid shield (95% coverage), Flamarrest® jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Coax AWG Stranding Conductor Material Dia. (mm)
1
18 Solid
BC - Bare Copper 1.016
Total Number of Conductors:
1
Insulation
Insulation Material:
Insulation Trade Name Insulation Material
Dia. (mm)
Teflon®
FFEP - Foam Fluorinated Ethylene Propylene 4.318
Outer Shield
Outer Shield Material:
Layer # Outer Shield Trade Name Type Outer Shield Material
Coverage (%)
1
Duofoil®
Tape Aluminum Foil-Polyester Tape-Aluminum Foil 100
2
Braid TC - Tinned Copper
95
Outer Jacket
Outer Jacket Material:
Outer Jacket Trade Name Outer Jacket Material
Flamarrest®
LS PVC - Low Smoke Polyvinyl Chloride
Overall Cable
Overall Nominal Diameter:
5.817 mm
Mechanical Characteristics (Overall)
Operating Temperature Range:
UL Temperature Rating:
Bulk Cable Weight:
Max. Recommended Pulling Tension:
Min. Bend Radius/Minor Axis:
-20°C To +75°C
75°C
61.016 Kg/Km
306.926 N
63.500 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification:
CMP
CEC/C(UL) Specification:
CMP
EU Directive 2011/65/EU (ROHS II):
Yes
EU CE Mark:
No
EU Directive 2000/53/EC (ELV):
Yes
EU Directive 2002/95/EC (RoHS):
Yes