English
Language : 

1347494 Datasheet, PDF (1/5 Pages) List of Unclassifed Manufacturers – 50 Ohm Transmission and Computer Cable
COAXIAL CABLES
6.67
50 Ohm Transmission and Computer Cable
RG-188A/U, RG-174/U and RG-58/U Type
Description
Part
No.
UL NEC/ Standard Lengths
C(UL) CEC
Type
Ft.
m
Standard
Unit Weight
Lbs. kg
Conductor
(stranding)
Diameter
Nom. DCR
Nominal
Core OD
Inch mm
Shielding Nominal OD
Materials
Nom. DCR Inch mm
Nom.
Imp.
Nom.
Vel.
of
Nominal
Capacitance
(Ω) Prop. pF/Ft. pF/m
Nominal
Attenuation
MHz
dB/ dB/
100 Ft. 100m
RG-174/U Type • 26 AWG Stranded (7x34) .019″ Bare Copper-covered Steel Conductor • Tinned Copper Braid Shield (90% Coverage)
Polyethylene Insulation • Black PVC Jacket
UL AWM
8216
—
100 30.5 1.1 .5 26 AWG .060 1.52 TC Braid .110 2.79 50 66% 30.8 101.0 1 1.9 6.2
Style 1354
500 152.4 5.0 2.3 (7x34)
90% Shield
10 3.3 10.8
(30V 75°C)
1000 †† 304.8
9.0 4.1 .019″
BCCS
97.0Ω/M′
318.2Ω/km
Coverage
10.7Ω/M′
35.1Ω/km
50 5.8 19.0
100 8.4 27.6
200 12.5 41.0
400 19.0 62.3
700 27.0 88.6
900 31.0 101.7
1000 34.0 111.5
RG-188A/U Type • 26 AWG Stranded (7x34) .020″ Silver-plated Copper-covered Steel Conductor • SPC Braid Shield (96% Coverage)
TFE Teflon® Insulation • White TFE Tape Jacket
200°C
VW-1
83269
—
100 †
500 †
1000 †
30.5 2.0
152.4 6.5
304.8 12.0
.9 26 AWG .058 1.47 SPC Braid .098 2.49
2.9 (7x34)
96% Shield
5.5 .020″
Coverage
SCCCS
8.5Ω/M′
91.2Ω/M′
27.9Ω/km
299.2Ω/km
MIL-C-17D
50 69.5% 29.0 95.1
1 1.2 3.9
10 2.7 8.9
50 5.6 18.4
100 8.3 27.2
200 12.0 39.4
400 17.5 57.4
700 23.7 77.8
900 27.3 89.6
1000 29.0 95.1
RG-58/U Type • 20 AWG Solid .033″ Bare Copper Conductor • Bare Copper Braid Shield (78% Coverage)
Polyethylene Insulation • Black PVC Jacket
80°C
9201
—
U-500 U-152.4 13.0 5.9 20 AWG .116 2.95 BC Braid .193 4.90 51.5 66% 28.5 93.5
1 .3 1.1
500 152.4 11.5 5.2 (solid)
78% Shield
10 1.1 3.6
U-1000 U-304.8
1000 304.8
25.0 11.4
23.0 10.4
.033″
BC
10.0Ω/M′
33.1Ω/km
Coverage
5.5Ω/M′
18.0Ω/km
50 2.5 8.2
100 3.8 12.5
200 5.6 18.4
400 8.4 27.6
700 11.7 38.4
900 13.7 44.9
1000 14.5 47.6
RG-58/U Type • 20 AWG Solid .033″ Bare Copper Conductor • Duobond® II + Tinned Copper Braid Shield (55% Coverage)
Polyethylene Insulation • Black PVC Jacket
UL AWM
Style 1354
(30V 60°C)
9310** —
500 152.4 10.5 4.8 20 AWG .114 2.90 Duobond II* .193 4.90 50 66% 30.8 101.0 1 .5 1.5
U-1000 U-304.8 22.0 10.0 (solid)
+ 55%
10 1.4 4.6
1000
304.8 21.0 9.5 .033″
BC
9.4Ω/M′
28.6Ω/km
TC Braid
8.0Ω/M′
24.4Ω/km
50 2.8 9.2
100 3.8 12.5
200 5.4 17.7
400 7.9 25.9
700 11.1 36.4
900 12.8 42.0
1000 13.9 45.6
BC = Bare Copper • BCCS = Bare Copper-covered Steel • DCR = DC Resistance • SCCCS = Silver-coated Copper-covered Steel • SPC = Silver-plated Copper • TC = Tinned Copper • TFE = Tetra Fluoroethylene
Contact the Belden Customer Service Department for a Comprehensive Connector Cross Reference. 1-800-BELDEN-1. Request quotations of RG/U cables not listed.
*Duobond II = Bonded Duofoil® (100% coverage) + aluminum braid (67% coverage).
**See Belden’s website, www.belden.com, for connector information.
† May contain more than one piece, min. length of any one piece is 25 ft.
††May contain more than one piece, min. length of any one piece is 100 ft. Length may vary ±10% from length shown.
Teflon is a DuPont trademark.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w. b e l d e n . c o m