English
Language : 

1347086 Datasheet, PDF (1/3 Pages) List of Unclassifed Manufacturers – 18 AWG stranded (19x30) tinned copper conductors
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
89740 Multi-Conductor - Audio, Control and Instrumentation Cable
For more Information
please call
1-800-Belden1
Description:
18 AWG stranded (19x30) tinned copper conductors, plenum, FEP insulation, twisted pair, FEP jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material
1
18 19x30 TC - Tinned Copper
Insulation
Insulation Material:
Insulation Material
Wall Thickness (mm)
FEP - Fluorinated Ethylene Propylene 0.1778
Outer Shield
Outer Shield Material:
Outer Shield Material
Unshielded
Outer Jacket
Outer Jacket Material:
Outer Jacket Trade Name Outer Jacket Material
Nom. Wall Thickness (mm)
Teflon®
FEP - Fluorinated Ethylene Propylene 0.2286
Overall Cabling
Overall Nominal Diameter:
Pair
Pair Color Code Chart:
Number Color
1
Black & Red
3.353 mm
Mechanical Characteristics (Overall)
Operating Temperature Range:
Bulk Cable Weight:
Max. Recommended Pulling Tension:
Min. Bend Radius (Install)/Minor Axis:
-70°C To +200°C
25.299 Kg/Km
217.962 N
35.560 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification:
CMP
CEC/C(UL) Specification:
CMP
EU CE Mark:
Yes
EU Directive 2000/53/EC (ELV):
Yes
EU Directive 2002/95/EC (RoHS):
Yes
EU RoHS Compliance Date (mm/dd/yyyy):
04/01/2005
EU Directive 2002/96/EC (WEEE):
Yes
Page 1 of 3
05-10-2011