English
Language : 

1345074 Datasheet, PDF (1/3 Pages) List of Unclassifed Manufacturers – 18 AWG stranded (19x30) TC conductors, plenum, FEP insulation
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
82760 Multi-Conductor - Single-Pair Cable
For more Information
please call
1-800-Belden1
Description:
18 AWG stranded (19x30) TC conductors, plenum, FEP insulation, twisted pair, overall Beldfoil® shield
(100% coverage), 20 AWG stranded TC drain wire, Flamarrest® jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material
1
18 19x30 TC - Tinned Copper
Insulation
Insulation Material:
Insulation Material
Wall Thickness (mm)
FEP - Fluorinated Ethylene Propylene 0.1778
Outer Shield
Outer Shield Material:
Outer Shield Trade Name Type Outer Shield Material
Coverage (%)
Beldfoil® with shorting fold Tape Aluminum Foil-Polyester Tape 100.000
Outer Shield Drain Wire AWG:
AWG Stranding Drain Wire Conductor Material
20 Stranded TC - Tinned Copper
Outer Jacket
Outer Jacket Material:
Outer Jacket Trade Name Outer Jacket Material
Nom. Wall Thickness (mm)
Flamarrest®
LS PVC - Low Smoke Polyvinyl Chloride 0.3556
Overall Cabling
Overall Nominal Diameter:
Pair
Pair Color Code Chart:
Number Color
1
Black & Red
3.708 mm
Mechanical Characteristics (Overall)
Operating Temperature Range:
Bulk Cable Weight:
Max. Recommended Pulling Tension:
Min. Bend Radius (Install)/Minor Axis:
-20°C To +75°C
33.485 Kg/Km
284.685 N
40.640 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification:
CMP
CEC/C(UL) Specification:
CMP
EU CE Mark:
Yes
Page 1 of 3
05-10-2011