English
Language : 

1344418 Datasheet, PDF (1/3 Pages) List of Unclassifed Manufacturers – 16 AWG stranded (19x29) TC conductors, polyethylene insulation
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
8719 Multi-Conductor - Single-Pair Cable
For more Information
please call
1-800-Belden1
Description:
16 AWG stranded (19x29) TC conductors, polyethylene insulation, twisted pair, overall Beldfoil® shield
(100% coverage), 18 AWG stranded TC drain wire, PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material
1
16 19x29 TC - Tinned Copper
Insulation
Insulation Material:
Insulation Material Wall Thickness (mm)
PE - Polyethylene 0.8128
Outer Shield
Outer Shield Material:
Outer Shield Trade Name Type Outer Shield Material
Coverage (%)
Beldfoil®
Tape Aluminum Foil-Polyester Tape w/Shorting Fold 100
Outer Shield Drain Wire AWG:
AWG Stranding Drain Wire Conductor Material
18 Stranded TC - Tinned Copper
Outer Jacket
Outer Jacket Material:
Outer Jacket Material Nom. Wall Thickness (mm)
PVC - Polyvinyl Chloride 0.8128
Overall Cabling
Overall Nominal Diameter:
Pair
Pair Color Code Chart:
Number Color
1
Black & Clear
Pair Lay Length & Direction:
Lay Length (mm) Twists/ft. (twist/m)
69.849725
14.436
7.950 mm
Mechanical Characteristics (Overall)
Operating Temperature Range:
UL Temperature Rating:
Bulk Cable Weight:
Max. Recommended Pulling Tension:
Min. Bend Radius (Install)/Minor Axis:
-20°C To +80°C
80°C (UL AWM Style 20253)
65.481 Kg/Km
453.716 N
76.200 mm
Page 1 of 3
05-10-2011