English
Language : 

123092A Datasheet, PDF (1/3 Pages) List of Unclassifed Manufacturers – ControlNet™ Quad Shielded Coax
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
123092A Coax - ControlNet™ Quad Shielded Coax
For more Information
please call
1-800-Belden1
General Description:
18 AWG solid bare copper-covered steel conductor, foam polyethylene insulation, Duobond IV® quad
shield (100% coverage), PVC inner jacket, aluminum interlocked armor, PVC sunlight-resistant outer jacket.
Usage (Overall)
Suitable Applications:
ControlNet™, Modbus II, Industrial Coax
Physical Characteristics (Overall)
Conductor
AWG:
# Coax AWG Stranding Conductor Material
Dia. (mm)
1
18 Solid
BCCS - Bare Copper Covered Steel 1.016
Total Number of Conductors:
1
Insulation
Insulation Material:
Insulation Material
Dia. (mm)
FPE - Foam Polyethylene 4.572
Inner Jacket
Inner Jacket Material:
Inner Jacket Material Nom. Dia. (mm)
PVC - Polyvinyl Chloride 7.569
Outer Shield
Outer Shield Material:
Layer # Outer Shield Trade Name Type Outer Shield Material
Coverage (%)
1
Bonded Duofoil®
Tape Bonded Aluminum Foil-Polyester Tape-Aluminum Foil 100
2
Braid AL - Aluminum
60
3
Duofoil®
Tape Aluminum Foil-Polyester Tape-Aluminum Foil
100
4
Braid AL - Aluminum
40
Outer Jacket
Outer Jacket Material:
Outer Jacket Material Nom. Wall Thickness (mm)
PVC - Polyvinyl Chloride 1.143
Armor
Armor Type:
Armor Material:
Diameter over Armor:
Overall Cable
Overall Nominal Diameter:
Interlocking
Aluminum
.501
15.011 mm
Mechanical Characteristics (Overall)
Operating Temperature Range:
Bulk Cable Weight:
Max. Recommended Pulling Tension:
-40°C To +75°C
211.324 Kg/Km
889.640 N
Page 1 of 3
10-30-2013