English
Language : 

MLX90110 Datasheet, PDF (8/10 Pages) List of Unclassifed Manufacturers – 128bit OTP/RW Transponder
MLX90110
128bit OTP/RW Transponder
Data encoding schemes
Manchester
For a “1” bit, there is a transition from 0 to 1 in the middle of the bit period. Reciprocal, for a “0” logic bit
there is a transition from 1 to 0 in the middle of the bit period.
Biphase
At the beginning of each bit, a transition will occur. A logic bit “1” will keep its state for the whole bit duration and a
logic bit “0” will show a transition in the middle of the bit duration.
Manchester Code
X Binary Data 1 1 1 1 0 1 0 1 1 0 0
Memory Output
Modulation Output
Biphase Code
X Binary Data 0 1 1 0 1 0 0 1 1 0 0
Memory Output
Modulation Output
Flow Chart.
Upon entering the RF field, the transponder "sees" increasing amplitude of the voltage between COIL and GND
pins. It passes through a POR sequence. Depending on the configuration bits it will enter the appropriate mode.
MLX90110 128bit MTP Transponder
Page 8 of 10
Rev 1.14 1-Dec-2000