English
Language : 

PE-5158X Datasheet, PDF (7/8 Pages) –
GENERAL PURPOSE
TRANSFORMERS
Control Transformers
Recognized component – Underwriter’s
Laboratories, Inc.
High dielectric strength capability
for industrial applications
High ET – product allows long
pulse width
Electrical Specifications @ 25°C — Operating Temperature 0°C to 70°C
Part
Number
PE-61001
PE-61003
PE-61006
PE-61007
PE-61008
PE-61014
PE-61015
PE-61017
PE-61018
PE-61019
PE-61023
Turns
Ratio
(±10%)
1:1
2:1
1:1:1
1:1:1
1:1:1
1:1
1:1
2:1
2:1
1:1:1
2:1:1
Primary Sine
Wave OCL
(mH MIN)
1.0
0.2
0.2
1.0
5.0
1.0
5.0
1.0
5.0
0.2
1.0
Primary PRI/SEC
ET-Constant Cww
(V-µs MIN) (pF MAX)
360
30
180
24
180
30
360
36
866
42
700
36
1500
42
700
36
1500
42
290
34
700
40
PRI/SEC
Leakage
Inductance
15.0
5.0
5.0
12.0
80.0
26.0
130.0
24.0
125.0
4.7
27.0
Primary
DCR
(Ω MAX)
2.8
1.4
—
2.8
6.0
3.0
6.3
3.0
6.3
1.4
3.0
Secondary
DCR
(Ω MAX)
3.1
0.9
1.5
3.6
7.2
3.2
7.0
2.0
4.0
1.5
2.0
Hi Pot*
PRI/SEC
(Vrms)
1600
1600
1600
1600
1600
2400
2400
2400
2400
2400
2400
*NOTE: PE-61001–PE-61023 Hi Pot SEC/SEC 300 Vrms. Average Power Rating: 2 Watts. UL-478 Recognized, File Number E52661.
Schematic/
Package
Style
A/TH11
A/TH11
B/TH11
B/TH11
B/TH11
A/TH12
A/TH12
A/TH12
A/TH12
B/TH12
B/TH12
A
5
6
Schematics
B
3 45 6
1
2
2 WINDING
12
3 WINDING
U.S: 858 674 8100 • U.K: 44 1483 401 700 • France: 33 3 84 35 04 04 • Singapore: 65 287 8998 • Taiwan: 886 2 2698 0228 • http://www.pulseeng.com
7
G008.A (2/00)