[Note 7] Measurement points
1/6Hp 1/2Hp 5/6Hp
1/6Vp
1/2Vp
1
2
3
Active area
5/6Vp
4
5
Vp: Total Number of Vertical pixel
Hp: Total Number of Horizontal pixel
[Note 8] Measurement condition
(1) Measurement equipment: BM-5A (TOPCON Corp.), Field=2 degree
(2) Ambient temperature Ta: 25 +/- 2 degC
(3) LCD: All pixels are WHITE, VDD=5.0V, fV=60Hz
(4) Measure after 30 minutes of Lamp warm up.
(5) IL=TBD mArms with the Lamp inverter TBD.
BACKLIGHT CHARACTERISTICS
This module is used the direct type backlight.
The backlight system is used 8 lamps.
The characteristics of single lamp are shown in the following tables.
Ta=25 degC
ITEM
Lamp voltage
Lamp current
Operating frequency
Start up voltage
Lamp life
SYM. CONDITIOS
VL
IL
fL
VS
tOL
MIN
-
TBD
TBD
-
TBD
TYP
TBD
-
TBD
-
-
MAX
-
TBD
TBD
TBD
-
UNIT
Vrms
mArms
kHz
Vrms
Hours
NOTE
at IL= TBD mArms
Recommended value
Recommended value
at Ta=0 degC
at IL= TBD mArms
[Note 1] Backlight driving conditions (operating frequency fL especially) may interfere with
horizontal frequency fH, causing the beat or flicker on the display.
Therefore the operating frequency fL shall be adjusted in relation to horizontal
frequency fH to avoid interference.
[Note 2] The inverter open voltage should be larger than start up voltage, otherwise backlight
may blinking for a moment after turns on or not be turned on. And this voltage should
be applied to Lamp for more than 1 second to start up, otherwise backlight may not
be turned on.
[Note 3] If driving current waveform is asymmetrical, mercury deviation inside of Lamp will
incline to one side and consequently abnormal lighting may occur.
To prevent such unfavorable lighting, driving current waveform is asked to have
unbalance rate of less than 10% and wave-height rate of less than 2 +/- 10%.
And this driving waveform shall be confirmed in your system.
Unbalance rate = | Ip - I-p | / IL x 100 (%)
Ip
Wave-height rate = Ip (or I-p) / IL
I-p
Current waveform
Ip : High peak value
I-p : Low peak value
IL : Effective value
[Note 4] The inverter of ground reference type should be used. The inverter of ground
floating type should not be used.
Tottori SANYO Electric Co., Ltd. TM150XG-76N08 Ver.1 Page 4/16