English
Language : 

ATR-S0203 Datasheet, PDF (4/5 Pages) List of Unclassifed Manufacturers – 1.25Gbps Single Mode SFP Transceiver (20km)
1.25Gbps Single Mode SFP Transceiver (20km)
ATR-S0203
5
MOD-DEF1 Module Definition 1
3
Note 3
6
MOD-DEF0 Module Definition 0
3
Note 3
7
Rate Select Not Connected
3
8
LOS
Loss of Signal
3
Note 4
9
VeeR
Receiver Ground
1
10
VeeR
Receiver Ground
1
11
VeeR
Receiver Ground
1
12
RD-
Inv. Received Data Out
3
Note 5
13
RD+
Received Data Out
3
Note 5
14
VeeR
Receiver Ground
1
15
VccR
Receiver Power
2
16
VccT
Transmitter Power
2
17
VeeT
Transmitter Ground
1
18
TD+
Transmit Data In
3
Note 6
19
TD-
Inv Transmit Data In
3
Note 6
20
VeeT
Transmitter Ground
1
Notes:
1. TX Fault is an open collector output, which should be pulled up with a 4.7K~10K. resistor on the host
board to a voltage between 2.0V and Vcc+0.3V. Logic 0 indicates normal operation; logic 1 indicates a laser
fault of some kind. In the low state, the output will be pulled to less than 0.8V.
2. TX Disable is an input that is used to shut down the transmitter optical output. It is pulled up within the
module with a 4.7K~10K. resistor. Its states are:
Low (0~0.8V) : Transmitter on
(>0.8V, <2.0V) : Undefined
High (2.0~3.465V) : Transmitter Disabled
Open : Transmitter Disabled.
3. MOD-DEF 0,1,2 are the module definition pins. They should be pulled up with a 4.7K~10K. resistor on
the host board. The pull-up voltage shall be VccT or VccR.
MOD-DEF 0 is grounded by the module to indicate that the module is present.
MOD-DEF 1 is the clock line of two wire serial interface for serial ID.
MOD-DEF 2 is the data line of two wire serial interface for serial ID.
4. LOS is an open collector output, which should be pulled up with a 4.7K~10K. resistor on the host board to
a voltage between 2.0V and Vcc+0.3V. Logic 0 indicates normal operation; logic 1 indicates loss of signal.
In the low state, the output will be pulled to less than 0.8V.
5. These are the differential receiver outputs. They are AC coupled 100. differential lines which should be
terminated with 100. (differential) at the user SERDES.
6. These are the differential transmitter inputs. They are AC-coupled, differential lines with 100.differential
termination inside the module.
„ Recommended Host Board Supply Filtering Network
No. 8, Jingwu Road
Ding Mao Development Zone
Zhenjiang 212009, China
Tel: (86)511-8885688(5088) Fax: (86)511-8889135
Email: sales@allrayinc.com, marketing@allrayinc.com