HA4812 Datasheet, PDF (3/3 Pages) List of Unclassifed Manufacturers – 12-90Amp 480 Vac AC Output | |||
|
◁ |
Series HA, Series HD
12-90Amp ⢠480 Vac⢠AC Output
50A
60
1ËC/W .5ËC/W
90
1.5ËC/W
40
100
2ËC/W
20
110
NO HEATSINK
120
0
10 20 30 40 50 20 40 60 80
Load Current [Arms]
Max Ambient Temp. [ËC]
CURRENT DERATING CURVES
12A
14
12
7ËC/W
3ËC/W
10
9ËC/W
110
5ËC/W
8
6
NO HEATSINK
115
4
120
2
0
02
120
80
4 6 8 10 12 20 40 60 80
Load Current [Arms]
Max Ambient Temp. [ËC]
75A
.5ËC/W
1ËC/W
95
.3ËC/W
100
110
40
120
0
15 30 45 60 75 20 40 60 80
Load Current [Arms]
Max Ambient Temp. [ËC]
25A
30
95
1ËC/W
25
100
3ËC/W 2ËC/W
20
15
110
10
NO HEATSINK
5
120
0
5 10 15 20 25 20 40 60 80
Load Current [Arms]
Max Ambient Temp. [ËC]
90A
120
90
.5ËC/W
.2ËC/W
.4ËC/W
100
80
1ºC/W
110
40
120
0
20 40 60 80 0 20 40 60 80
Load Current [Arms]
Max Ambient Temp. [ËC]
© 2002 CRYDOM CORP, Specifications subject to change without notice.
FastFax Document No. 158
SERIES HA/HD.
REV. 031802
PAGE 3 OF 3
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 ⢠FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
|