English
Language : 

SCXL004DN Datasheet, PDF (2/3 Pages) List of Unclassifed Manufacturers – Precision Compensated, Low Pressure Sensors
SCXL004DN
Precision Compensated, Low Pressure Sensors
PRESSURE SENSOR CHARACTERISTICS
MAXIMUM RATINGS
Supply Voltage VS
Common-mode Pressure
Lead Temperature (Soldering, 4 seconds)
Proof Pressure
Burst Pressure
+18 VDC
150 In. H2O
250°C
10 In. H2O
5 psi
ENVIRONMENTAL SPECIFICATIONS
Temperature Range
Compensated
Operating
Storage
Humidity Limits
0 to 50°C
0°C to 70°C
0°C to 70°C
0 to 80 %RH
WARNING:
Due to the delicate nature of these very
sensitive devices, some special handling is
required. Parts are sensitive to shock and
vibration and must be handled with care.
Dropping on any hard surface (bench top etc.)
can destroy the device. Note 10 In. H O max.
2
overpressure.
SCXL004 PERFORMANCE CHARACTERISTICS
Characteristic
Min.
Operating Pressure Range
---
Sensitivity
---
Full-scale Span2
38
Zero Pressure Offset
-1.5
Combined Linearity and Hysteresis3
---
Temperature Effect on Span (0-50°C)4
---
Temperature Effect on Offset (0-50°C)4
---
Repeatability5
---
Input Impedance6
---
Output Impedance7
---
Common-mode Voltage8
5.7
Response Time9
---
Long Term Stability of Offset and Span10
---
Position Sensitivity
---
Proof Pressure11
---
Typ.
---
10
40
0
±0.5
±0.5
±0.50
±0.2
4.0
4.0
6.0
500
±0.5
0.25
10
Max.
4
---
42
1.5
±1.0
±2.0
±1.5
---
---
---
6.3
---
---
---
---
Unit
In. H O
2
mV/In. H2O
mV
mV
%FS
%FS
mV
%FS
kΩ
kΩ
VDC
µs
%FS
mV/g
In. H O
2
SPECIFICATION NOTES:
1. Reference conditions: Unless otherwise noted: Supply voltage, VS = 12 V, TA = 25°C, Common-mode Line Pressure = 0 psig, Pressure Applied to Port B.
2. Span is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure. Span is ratiometric to the supply voltage.
3. Zero pressure effect is measured with pins pointed towards the ground. Offset can be position sensitive.
4. Maximum error band of the offset voltage and the error band of the span, relative to the 25°C reading.
5. Maximum difference in output at any pressure with the operating pressure range and temperature within 0°C to +50°C after:
a) 100 temperature cycles, 0°C to 50°C
b) 1.0 million pressure cycles, 0 psi to full-scale span
6. Input impedance is the impedance between pins 2 and 4.
7. Output impedance is the impedance between pins 3 and 5.
8. This is the common-mode voltage of the output arms (Pins 3 and 5) for VS = 12 V.
9. Response time for a 0 psi to full-scale span pressure step change, 10% to 90% rise time.
10. Long term stability over a one year period.
11. Proof pressure is the pressure above which devices will not return to guaranteed specifications.
January 1998/043
Aubinger Weg 27, 82178 Puchheim, Germany
Phone 0049 - (0) 89 80 08 30, Fax 0049 - (0) 89 8 00 83 33
http://www.sensortechnics.com