English
Language : 

PCI350 Datasheet, PDF (2/5 Pages) List of Unclassifed Manufacturers – 350 Watt CompactPCI Power Supply
PCI 350
350 Watt CompactPCI Power Supply
TracewellPower
Specifications
Output Voltage/Current Options ... 5V/40A, 3.3V/25A, +12V/9A, -12V/2A
5V/50A, 3.3V/25A, +12V/9A, -12V/2A
3.3V/50A, 5V/20A, +12V/9A, -12V/2A
3.3V/60A, 5V/20A, +12V/9A, -12V/2A
Output Power........................................... DC Input:
AC Input:
350 Watts max
350 Watts max 105-264 Vac
300 Watts max 90-105 Vac
Input Voltage/Current ......................... AC: 100-240 Vac (90-264 Vac tolerant range), 47-63Hz,
6 A max, single phase
DC: 48 Vdc (40-72 Vdc tolerant range), 12 A max
Power Factor............................................. 0.99 typical
Inrush Current.......................................... AC: 40A max
DC: 15A max
Efficiency .................................................... DC input: 75% min
AC input: 65% min
Efficiency increases with line voltage
Holdup Time ............................................. 20 msec min. from input power failure until FAIL# signal
drops, at full load and 90-264 Vac
AC Fail Warning....................................... 5 msec min.continued operation after FAIL# signal drops
Paralleling.................................................. Any number of power supplies can be operated in
parallel and will share 3.3V/5V/+12V current to within
10%. Remote Sense must be used when paralleling
with current sharing
Redundant/Hot Swap........................... Full power N+1 redundant and hot-swap
Remote Sense........................................... Compensates for up to 0.25V total distribution voltage
drop on the 3.3V/5V/+12V outputs
Line/Load Regulation........................... 1% max. over input range and 0-100% load except
-12V output which is ±10%
Minimum Load......................................... None required
Ripple/Noise ............................................. 50 mV max. for all outputs, peak-to-peak, DC to 20 MHz
with coaxial probe and 0.1uF/22uF capacitors at the
connector
Overshoot/Undershoot ....................... None at turn-on or turn-off
Turn-on Time ............................................ 1 sec max. from power up. All output voltages come
up within 10 msec of each other.
Over-Voltage ............................................ Shutdown at 130% of nominal Vout. Recycle power to
reset
Over-Temperature................................. Shutdown upon internal heatsink temperatures
exceeding limits. Recycle power to reset
Current Limiting ..................................... All outputs protected against overload and short circuit.
Straight-line current limiting, does not fold-back or latch-
up during startup or load transients. Automatic recovery
Safety. .......................................................... UL, cUL, and CB report UL1950 and EN60950
EMC ............................................................... Emissions below EN55022 class A and EN61000-3-2, 3.
Immunity to EN61000-4-2, 4, 5
Input Fuse. ................................................. Internal fusing included
Output Isolation...................................... All outputs and control signals are SELV circuits
referenced to GND with reinforced insulation to the AC
primary. GND should be connected to chassis ground
in the system.
Leakage Current ..................................... 1.0 mA max. at 240 Vac
Dielectric Strength................................. AC: 2200 Vdc from input to chassis ground
DC: 500 Vdc from input to chassis ground
Indicators ................................................... Green LED indicating INPUT OK
Red LED indicating a power supply FAULT
Connector .................................................. Positronic part no. PCI38M400A1
Mating connector part no. PCI38F300A1
Cooling ........................................................ 15 cfm/400 lfm forced air required through power
supply cooling fins and enclosure
Operating Temperature...................... -20°C to 50°C operating temperature with specified air
flow. Derate output power with reduced airflow
conditions (consult factory)
Storage Temperature........................... -40°C to 85°C
Shock/Vibration...................................... Ruggedized construction
Note: Specifications subject to change without notice
PCI 350 Status Indications
Condition
EN# low, Inputs/Outputs OK
INH# signal low
INH# high, EN# high
Inhibit switch depressed
Low AC or DC input
Internal over-temperature
Output under-voltage
Output over-voltage
Ouput short circuit
Power Supply
On/Off
ON
OFF
OFF
OFF
OFF
OFF
OFF**
OFF**
OFF**
Input OK LED
ON
ON
ON
ON
OFF
ON
ON
ON
ON
Fault LED
OFF
ON
ON
ON
ON*
ON
ON
ON
ON
* If the input is below approx. 20 V, the FAULT LED will not illuminate
** Typically, only the ouptut exhibiting the fault conditions will be off
FAIL #
OPEN
LOW
LOW
LOW
LOW
LOW
LOW
LOW
LOW
www.tracewellpower.com 1.800.811.1480 phone 614.847.9336 fax 614.847.9316 567 Enterprise Drive Westerville, Ohio 43081