English
Language : 

APM-A3A1 Datasheet, PDF (2/6 Pages) List of Unclassifed Manufacturers – APM Series Compact Proximity Sensors
• DC 2-wire type
Appearance
Sensor package style
Dimensions (mm)
WDH
Top sensing type
8DH
(sensing face)
D=5.9 H=9.4
(body)
D=21.6 H=5.9
Side sensing type
8 25 5.9
Sensing
distance
(mm)
2.5
Side sensing type
8 25 7.5
Location
of sensing
face
Top
Side
Side
Locking
boss
Not
provided
Provided
Not
provided
Provided
Not
provided
Provided
Operation
mode
N.O.
N.C.
N.O.
N.C.
N.O.
N.C.
N.O.
N.C.
N.O.
N.C.
N.O.
N.C.
Catalog listing
APM-A3J1
APM-A3K1
APM-B3J1
APM-B3K1
APM-C3J1
APM-C3K1
APM-D3J1
APM-D3K1
APM-C3J1-S
APM-C3K1-S
APM-D3J1-S
APM-D3K1-S
SPECIFICATIONS
• DC 3-wire type
Item
Actuation method
Rated supply voltage
Rated sensing distance
Usable sensing distance
Standard target object
Differential travel
Operating voltage range
Current consumption
Output mode
Operation mode
Control
output
Switching current
Voltage drop
Output dielectric strength
Operating frequency
Hysteresis
Temperature characteristics
Supply voltage characteristics
Indicator lamps
Operating temperature range
Storage temperature range
Operating humidity range
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Protection
Weight
Circuit protection
Wiring method
Case material
Tightening torque
Standard catalog listing
APM- 3A1 (-S)
APM- 3B1 (-S)
APM- 3D1
APM- 3E1
High-frequency oscillation type (unshielded type)
12/24Vdc
2.5mm, 15%
0 to 1.8mm
15 15mm, 1mm thick iron
15% max. of sensing distance
10.8 to 26.4Vdc (ripple voltage 10% max.)
10mA max.
NPN transistor open collector
PNP transistor open collector
Normally open (N.O.) Normally closed (N.C.) Normally open (N.O.) Normally closed (N.C.)
30mA max. (resistive load)
1V max. (switching current 30mA)
26.4V
120Hz
0.05mm max.
15% max. for the range of ~10 to +55˚C when +25˚C is taken as standard temperature in sensing distance
2% max. with 10% voltage fluctuation with rated supply voltage as standard voltage in sensing distance
Lights (red) when object approaches
~10 to +55˚C
~25 to +70˚C
35 to 85% RH
50M min. (by 500Vdc megger)
1,000Vac, 50/60Hz for 1 minute between case and electrically live metals
10 to 55Hz, 1.5mm peak-to-peak amplitude, 2hrs in X, Y and Z directions
500m/s2 3 times in X, Y and Z directions
IP67 (IEC 529)
Approx. 10g
Surge absorption, reverse connection protection circuit
Pre-leaded (oil-resistant cord: 2.5mm O.D., 0.08mm2, 3-core, 1m)
Polyalylate resin
0.5N-m (M2.6 screw)
• Installation Instructions No.: CP-UM-3162E
Note:
Normally open: Load operates when object approaches the sensor (output circuit ON when detected).
Normally closed: Load is reset when object approaches the sensor (output circuit ON when not detected).