English
Language : 

9841 Datasheet, PDF (2/3 Pages) List of Unclassifed Manufacturers – Low Capacitance EIA RS-485
9841 Paired - Low Capacitance EIA RS-485
Outer Shield Drain Wire Stranding
Outer Shield Drain Wire Conductor Material
OUTER JACKET:
7x32
TC - Tinned Copper
Outer Jacket Material
OVERALL NOMINAL DIAMETER:
PVC - Polyvinyl Chloride
Overall Nominal Diameter
MECHANICAL CHARACTERISTICS:
.232 in.
Operating Temperature Range
UL Temperature Rating
Bulk Cable Weight
Max. Recommended Pulling Tension
Min. Bend Radius (Install)
-30°C To +80°C
80°C
36 lbs/1000 ft.
72.3 lbs.
2.5 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE:
APPLICABLE STANDARDS:
NEC/(UL) Specification
CEC/C(UL) Specification
AWM Specification
PLENUM/NON-PLENUM:
CM
CM
2919 (30 V)
Plenum (Y/N)
Plenum Number
ELECTRICAL CHARACTERISTICS:
N
82841, 89841
Nom. Characteristic Impedance
Nom. Capacitance Conductor to Conductor @ 1 KHz
Nom. Cap. Cond. to Other Cond. & Shield @ 1 KHz
Nominal Velocity of Propagation
Nominal Delay
Nom. Conductor DC Resistance @ 20 Deg. C
Nominal Outer Shield DC Resistance @ 20 Deg. C
Nom. Attenuation (dB/100 ft)
Max. Operating Voltage - UL
Other Maximum Continuous Currents
120 Ohms
12.8 pF/ft
23 pF/ft
66 %
1.6 ns/ft
24 Ohms/1000 ft
3.4 Ohms/1000 ft
0.6 (@ 1 MHz) dB/100 ft.
300 V RMS
2.1 Amps per conductor @ 25°C
PUT-UPS AND COLORS:
Item
Description
Put-Up (ft.)
9841 060100
1 PR #24 PE SH PVC 100
9841 0601000
1 PR #24 PE SH PVC 1000
Ship Weight (lbs.)
4.3
40
Jacket Color
CHROME
CHROME
Page 2 of 3
Notes
C