XE5690SM Datasheet, PDF (11/16 Pages) List of Unclassifed Manufacturers – Compact, Low-Cost Global Embedded Modem
AT COMMANDS
An asterisk indicates the factory default
A Answer Command - forces the smart transceiver
respond to a summons from another wireless device.
Dn Initiate a Wireless Link - attempts to establish a
connection with the transceiver at address n.
En Echo Characters - determines if the XE900S-500 will
echo the characters received on its serial interface during
command mode.
n=0 Characters not Echoed
n=1 Characters Echoed *
In Identification - displays product identification code.
n=0 Display Product Code
n=1 Display Product Name
n=2 Display Model Number
n=3 Display Copyright
n=4 Display Firmware Revision
Qn Result Code Display - determines if result codes will
be displayed.
n=0 Display Result Codes *
n=1 Do not Display Result Codes
Sn= Set Value of Register Sn
Sn? Read Value of Register Sn
Vn Response Type - selects Full Word or Numeric
responses
n=0 Numeric Responses
n=1 Full Word Responses *
Zn Reset - executes a soft Reset
n=0 Reset to Values Stored in User Profile 0 *.
n=1 Reset to Values Stored in User Profile 1
&F Restore Factory Settings - returns all configuration
commands and registers to their factory default values.
&IAn? Read Local Analog Input “n” - This command allows
the host equipment to read the values of the local analog
inputs.
n=0 Read input ADC0
n=1 Read input ADC1
&IDn? Read Local Digital Input “n” - This command allows
the host equipment to read the status of the local digital
inputs.
n=0 Read input DIO0
n=1 Read input DIO1
n=2 Read input DIO2
n=3 Read input DIO3
n=4 Read input DIO4 (pin shared with ADC0)
n=5 Read input DIO5 (pin shared with ADC1)
&IDn=z Set Local Digital Output “n” - This command
allows the host equipment to set the condition of the
local digital outputs. When z=0 the output is set to a
logic low; when z=1 the output is set to a logic high.
n=0 Set output DIO0
n=1 Set output DIO1
n=2 Set output DIO2
n=3 Set output DIO3
&Kn Flow Control - selects the type of flow control to be
used between the system host and the XE900S-500
n=0 Flow Control Disabled
n=3 RTS/CTS, hardware Flow Control
n=4 XON/XOFF, in-band Flow Control
&V View Active Configuration - sends the active
configuration data to the system host.
&Wn Store Current Configuration - loads the current
XE900S-500 configuration into either User Profile 0 or
User Profile 1.
n=0 load configuration into User Profile 0
n=1 load configuration into User Profile 1
#B Wireless Broadcast Mode - initiates wireless broadcast
mode for diagnostic purposes.
#C Count-Off Request (ASCII) - Initiates a “count-off’
sequence in the network with node status to be reported
in ASCII format.
#E: Count-Off Response (ASCII) - Programs the nodes 8
byte response to a “count-off’ request from the network
hub in ASCII format.
#E= Count-Off Response (Hex) - Programs the nodes 8
byte response to a “count-off’ request from the network
hub in hexadecimal format.
XECOM
(11)
XE900S-500