DATA SHEET
MRT
TXC-02050C
ABSOLUTE MAXIMUM RATINGS
Parameter
Supply voltage
AGC Supply Voltage
DC input voltage
Continuous power dissipation
Ambient operating temperature
Operating junction temperature
Storage temperature range
Symbol
VDD
VAGC
VIN
PC
TA
TJ
TS
Min *
-0.3
-0.5
-0.5
-40
-55
Max *
+7.0
+6.5
VDD + 0.5
750
85
125
150
Unit
V
V
V
mW
oC
oC
oC
*Note: Operating conditions exceeding those listed in Absolute Maximum Ratings may cause permanent failure. Expo-
sure to absolute maximum ratings for extended periods may impair device reliability.
THERMAL CHARACTERISTICS
Parameter
Thermal Resistance:
junction to ambient
Min
Typ
Max
Unit
Test Conditions
46
oC/W 0 ft/min linear airflow
POWER REQUIREMENTS
VDD
VAGC
Parameter
IDD
IAGC
PDD
PAGC
Min
Typ
Max
Unit
Test Conditions
4.75
5.0
5.25
V
VDD - 0.3
VDD - 0.62
V
Derived from VDD via a
1N914 or 1N4148 diode.
100
mA VDD = 5.25V
20
mA VAGC = 4.63V
525
mW VDD = 5.25V *
93
mW VAGC = 4.75V *
* with inputs switching and outputs terminated.
- 11 of 36 -
TXC-02050C-MB
Ed. 1, May 2002