English
Language : 

FM24C16A Datasheet, PDF (11/13 Pages) List of Unclassifed Manufacturers – 16Kb FRAM Serial Memory
FM24C16A
Diagram Notes
All start and stop timing parameters apply to both read and write cycles. Clock specifications are identical for read
and write cycles. Write timing parameters apply to slave address, word address, and write data bits. Functional
relationships are illustrated in the relevant data sheet sections. These diagrams illustrate the timing parameters only.
Read Bus Timing
tR
tHIGH
tF
tLOW
tSP
tSP
SCL
tSU:SDA
tBUF
SDA
1/fSCL
tHD:DAT
tSU:D AT
Start
Stop Start
tAA
tDH
Acknowledge
Write Bus Timing
SCL
SDA
tSU:STO
t
HD:STA
tHD:DAT
tSU:DAT
Start
Stop Start
tAA
Acknowledge
Data Retention (VDD = 4.5V to 5.5V unless otherwise specified)
Parameter
Min
Units
Notes
Data Retention
10
Years
1
Notes
1. The relationship between retention, temperature, and the associated reliability
level is characterized in a separate reliability report.
Rev 0.1
June 2002
Page 11 of 13