English
Language : 

D4DS Datasheet, PDF (11/12 Pages) List of Unclassifed Manufacturers – Safety-Door Switch
D4DS
Operation Key Mounting Dimensions
Horizontal/Vertical Mounting
D4DS-K1 or D4DS-K2
Two, M4
Adjustable Mounting (Horizontal) D4DS-K3
Two, M4
Adjustable Mounting (Horizontal/Vertical) D4DS-K5
41±0.1
43±0.1
Two, M4
886-3-5753170
86-755-83289224
Http://www.100y.com.tw
Securing the Door
When the door is closed (with the Operation Key inserted), the
door (or the Operation Key) may be pushed back across the set
zone due to the door’s weight, the door cushion rubber, etc. If
load is applied to the Operation Key, the door may fail to unlock.
Secure the door with hooks so that it will remain within in the set
zone.
Set zone
(0.5 to 3 mm)
Operation Key
Changes in Head Mounting Direction
By removing the screws on the four corners of the head, the
head can be reset in any of four directions.
When changing the head mounting direction, make sure that the
Operation Key is in the head.
Make sure that no foreign materials penetrate through the
mounting holes of the head. Internal screws of the head must not
be removed, or the internal parts of the head may be lost or
deformed.
Wiring
Do not connect lead wires directly to the terminals. Be sure
to connect the lead wires through insulation tubes and crimp
terminals., and tighten each terminal screw within an
optimum torque range. The lead wires must be an AWG20 to
AWG14 type (i.e., 0.5 to 25 mm2 thick).
dz dia.:
D dia.:
B:
L:
F:
I:
3.7
4.5
7.0
20.2
7.7
9.0 (mm)
D dia.
dz dia.
12