English
Language : 

WR24D15 Datasheet, PDF (1/2 Pages) List of Unclassifed Manufacturers – 15 Watt Wide input DC/DC converters
WR-XC and WR-MP SERIES
Single and dual output
[ 2 YEAR WARRANTY ]
• 2:1 input range
• WR-XC UL approved
• Efficiency to 86%
• Isolated outputs
• Six sided shield
• Remote on/off control on XC models
• 100kHz switching frequency
• Two package sizes available
The WR series DC/DC converters accept a wide input voltage range of 9-
18VDC, 18-36VDC or 36-72VDC. A 100kHz switching regulator produces
operating efficiencies up to 86% at full load and as high as 80% at light load. In
the case of duals, full power may be taken from either output. All models will
tolerate a short circuit between positive and negative outputs or between either
output and common indefinitely. Load regulation of ±1%, line regulation of
±0.2%, Pi input filtering and remote on/off control (XC package only) which can
be improvised as an undervoltage shutdown signal, are featured on all models.
Six-sided continuous EMI/RFI shielding is provided in both XC and MP
packages. The operating temperature range is –25°C to +71°C convection
cooled, with no derating required.
SPECIFICATION All specifications are typical at nominal input, full load at 25°C unless otherwise stated
OUTPUT SPECIFICATIONS
GENERAL SPECIFICATIONS
Voltage accuracy
±1.0%
Efficiency
Full load. See table
75%, min.
Voltage balance
Voltage adjustability
Dual outputs
WR/XC, single output
±2.0%
±10% max.
Isolation voltage
See Note 4
WR/MP, Input/output
WR/XC, Input/output
WR/XC, output/case
500VDC
500VDC
250VDC
Line regulation
HL-LL
±0.2%
Switching frequency Fixed
100kHz
Load regulation
FL-NL
FL-0.25% FL
±5.0%, max.
±1.0%, max.
Approvals and
standards
Safety (WR-XC)
UL478
Ripple and noise
5Hz to 20MHz
75mV pk-pk,
10mV rms max.
Transient response
25% step load
change
±1.0% error band
500µs recovery
Temperature coefficient
±0.02%/°C, max.
Overvoltage protection 5V single output
(Zener clamp)
12 and 15V singles
6.8V ±10%
18.0V ±10%
Short circuit protection
Continuous
automatic recovery
INPUT SPECIFICATIONS
Input voltage range
12VDC
24VDC
48VDC
9-18VDC
18-36VDC
36-72VDC
No load input current 12VDC
24VDC and 48VDC
30mA
20mA
Input filter
Pi type
Remote ON/OFF
Logic compatibility
Ec-ON
Ec-OFF
Shutdown idle current
Input resistance
Control common
Refers to XC package only
CMOS or open collector TTL
+5.5VDC or open-circuit
1.8VDC
5mA
0VDC <Ein< 9VDC; 100kΩ
Referenced to input minus
Case material
XC case
MP case
Black coated metal
with non-conductive base
Non-conductive
black plastic
Material flammability
UL94V-0
Weight
XC case
MP case
170g (6.0oz.)
200g (7.06oz.)
MTBF
See Note 6
840,000 Hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Operating ambient -25°C to +71°C
Non-operating amb. -55°C to +105°C
Case temp. rise
+30°C at FL max.
Derating
None required
Cooling Free air convection cooled
Relative humidity
Non-condensing
5% to 95% RH
Altitude
Operating
Non operating
10,000 feet max.
40,000 feet max.
Vibration
5Hz to 500Hz
2.5G rms (approx.)
International Safety Standard Approvals
UL478 File No. E131987 (WR-XC)
Data Sheet © Artesyn Technologies® 2000
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
PAGE 1