LPT60 Datasheet, PDF (1/2 Pages) List of Unclassifed Manufacturers – Universal input, Remote sense on main output, Low output ripple, Overvoltage protection
60 Watts
LPT60 Series
Total Power:
Input Voltage:
# of Outputs:
60-80 Watts
85-264 VAC
120-300 VDC
Triple
Special Features
• Universal input
• 3” x 5” footprint
• Remote sense on main output
• Built-in EMI filter
• Low output ripple
• Adjustable main output
• Overvoltage protection
• Overload protection
• 110 KHz switching frequency
• LPX60 enclosure kit available
Environmental
Operating temperature: 0° to 50°C ambient
derate each output at 2.5% per degree from
50° to 70°C
Electromagnetic susceptibility: designed to meet
IEC 801, -2, -3, -4, -5, -6, Level 3
Humidity: Operating; non-condensing
5% to 95%
Vibration: Three orthogonal axes, sweep at
1 oct/min, 5 min. dwell at four major resonances
0.75G peak 5 Hz to 500 Hz, operational
Storage temperature: -40° to 85°C
Temperature coefficient: ±.04% per °C
MTBF demonstrated: >550,000 hours at full load
and 25°C ambient conditions
Electrical Specs
Input
Input range
Frequency
Inrush current
Input current
Efficiency
EMI filter
Safety ground
leakage current
Output
Maximum power
Adjustment range
Cross regulation
Hold-up time
Overload protection
Overvoltage protection
Remote sense
85-264 VAC
120-300 VDC
47-440 Hz
<18 A peak @ 115 VAC;
<36 A peak @ 230 VAC,
cold start @ 25°C
1.5 A max. (RMS) @ 115 VAC
70% typical at full load (60% for
LPT61)
FCC Class B conducted
CISPR 22 Class B conducted
EN55022 Class B conducted
VDE 0878 PT3 Class B conducted
<0.5 mA @ 50/60 Hz, 264 VAC input
60 W for convection (LPT61, 35 W);
80 W with 30 CFM forced air (LPT61,
55 W)
-5, +10% minimum
±2% on output 1;
±5% on outputs 2,3
20 ms @ 60 W load, 115 VAC nominal
line
Short circuit protection on all
outputs. Case overload protected @
110-145%
above peak rating
5.7-6.7 VDC on main output
LPT61: 3.6 to 4.6 VDC
Compensates for 0.5 V lead drop min.
Will operate without remote sense
connected. Reverse connection
protected.
Safety
VDE 0805/EN60950 (IEC950)
UL
UL1950
CSA CSA 22.2-234 Level 3
NEMKO EN 60950/EMKO-TUE
(74-sec) 203
BABT EN60950/BS7002
CB
Certificate and report
CE
Mark (LVD)
11774-3336-1255 (LC #86665)
E132002
LR53982C
P95100123
PS / 605273
1518, 1519, 1520