English
Language : 

LF580 Datasheet, PDF (1/4 Pages) List of Unclassifed Manufacturers – Dual, Continuous, Analog Highpass Filter
Dual, Continuous, Analog
Highpass Filter
LF580 DATA SHEET
FEATURES
DESCRIPTION
• only 2 small capacitors required
• 200 to 10 kHz adjustable corner frequency
• dual 12 dB/Oct Butterworth filter (24 dB/Oct cascaded)
• 1.1 to 3.0 VDC operating range
• adjustable by a single potentiometer
The LF580 continuous analog filter consists of two second
order (12 dB/oct), tunable (0.2 to 10 kHz) highpass Butterworth
filter blocks.
Tracking and corner frequency of each block are controlled
by a single potentiometer. Cascading the two blocks
together results in a single 24dB/oct high pass filter requiring
only two external 0.001 µF capacitors for the filter response.
STANDARD PACKAGING
• 8 pin MICROpac
• 8 pin PLID ®
• Chip (66 x 61mils)
The output noise of each filter stage is typically 5.6µV.
Cascading the two filter blocks together will produce a
noise level which is
VN = (VN1)2 + (VN2)2
Where VN is the total output noise of both filters, VN1 and
VN2 is the noise of each filter.
To improve the signal-to-noise ratio of the filter the LF580
should be placed after a preamplifier, provided that the
signal level does not exceed the maximum signal capability
of 50mVRMS
VB
4
8
AIN
0.001
+
A
_
0.001
+
B
_
5
BOUT
CONTROL
7
6
AOUT
BIN
1.8k
3
1
CONTROL GND
All resistors in ohms, all capacitors in microfarads unless otherwise stated
BLOCK DIAGRAM
Revision Date: January 2001
Document No. 500 - 73 - 08
GENNUM CORPORATION P.O. Box 489, Stn. A, Burlington, Ontario, Canada L7R 3Y3 tel. +1 (905) 632-2996
Web Site: www.gennum.com E-mail: hipinfo@gennum.com