English
Language : 

7PCV2415 Datasheet, PDF (1/2 Pages) List of Unclassifed Manufacturers – Analog Input Power Controller
Series PCV
Analog Input Power Controller
• Operates at 60Hz & 50Hz
• Internal Snubber
• Industry Standard Package
• Control Circuit Requires No
Adjustment or Calibration
The PCV Series proportional controllers
are self contained power control mod-
ules integrating a complete phase fired
logic control system and a solid state
relay in the same standard package.
Typical applications include heaters,
vibratory feeders and tungsten lamps.
MODEL NUMBERS
OUTPUT SPECIFICATIONS➀
Operating Voltage (47-63 Hz) [Vrms]
Max. Load Current Range [Arms]
Transient Overvoltage [Vpk]
Max. Surge Current, (1 Cycle) [Apk]
Max. Off-State Leakage Current @ Rated Voltage [mA]
Maximum I 2 t for Fusing (8.3 msec) [A 2sec]
Maximum Voltage Drop (100% On) [Vpk]
Minimum Off-State dv/dt [V/µsec]
Power Factor (Min.) with Max. Load
INPUT SPECIFICATIONS ➀
Control Voltage Range
Typical Input Current @ 5 Vdc
GENERAL NOTES
➀ All parameters at 25º C unless otherwise specified.
7PCV2415 7PCV2425
10PCV2415 10PCV2425 10PCV2450 10PCV2475 10PCV2490
100-240
.15-15
600
150
10
94
1.6
200
0.5
100-240
.15-25
600
250
15
260
1.6
200
0.5
100-240
.15-50
600
625
20
1620
1.6
200
0.5
100-240
.15-75
600
1000
20
4150
1.6
200
0.5
100-240
.15-90
600
1200
20
6000
1.6
200
0.5
7PCV24xx
2-7 Vdc
10PCV24xx
2-10 Vdc
4 mA
4 mA
© 2002 CRYDOM CORP, Specifications subject to change without notice.
TYPICAL APPLICATIONS
• Industrial Temperature Controllers
• Light Dimming
• Vibratory Feeders
• Resistive Heating Elements
• Conveyor Speed Control
UNSUITABLE APPLICATIONS
The PCV is not suitable for some load applications
including, but not limited to the following:
• AC Motor Control
• Three Phase Motors
• Transformers requiring pure sine wave input
• Zero Crossing Applications
Please contact Crydom’s application
engineering department for additional
information and specific application
questions.
FastFax Document No. 204
SERIES PCV.
Rev. 041902
PAGE 1 OF 2
Percentage On vs. Input Voltage
100
80
60
40
50 Hz
20
60 Hz
0
2.5 3.5 4.5 5.5 6.5 7.5 8.5 9.5
Input Voltage
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506