English
Language : 

1140-F111-P1M1-10A Datasheet, PDF (1/4 Pages) List of Unclassifed Manufacturers – Thermal Overcurrent Circuit Breaker
Thermal Overcurrent Circuit Breaker 1140-...
Description
Miniaturised single pole thermal circuit breaker with push-to-reset
tease-free, trip-free, snap action mechanism (R-type TO CBE to EN
60934). Available in versions for panel mounting, snap-in or threadneck,
or as an integral type. For lower current ratings see types 104, 105, 106.
Approved to CBE standard EN 60934 (IEC 60934).
Typical applications
Motors, transformers, solenoids, hand-held machines and appliances.
1140-E...
1
1140-F...
1140-G.1.
Ordering information
Technical data
Type No.
1140 single pole thermal circuit breaker
Mounting
E2 integral mounting
F1 snap-in panel mounting
G1 threadneck panel mounting 3/8-27UNS with hex nut and knurled nut *
G2 threadneck panel mounting 3/8-27UNS for standard fuseholder cut-out*
with plastic knurled nut
Number of poles
1 1 pole protected
Actuator style
1 black push button (standard)
Terminal design
P1 blade terminals A6.3-0.8 (QC .250)
Characteristic curve
M1 medium delay
Current ratings
3.5...16 A
1140 - F1 1 1 - P1 M1 - 10 A ordering example
*mounting hardware bulk shipped
Packaging quantity: 125 pcs
Standard current ratings and typical internal resistance values
Current
rating (A)
3.5
4
5
6
7
8
Internal
resistance (Ω)
0.06
0.04
0.03
0.02
< 0.02
< 0.02
Current
rating (A)
10
12
13
15
16
Internal
resistance (Ω)
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
Voltage rating
Current ratings
Typical life
Ambient temperature
Insulation co-ordination
(IEC 60664 and 60664A)
Dielectric strength
(IEC 60664 and 60664A)
operating area
Insulation resistance
Interrupting capacity Icn
Interrupting capacity
(UL 1077)
Degree of protection
(IEC 60529/DIN 40 050)
Vibration
Shock
Corrosion
Humidity
Mass
AC 240 V; DC 48 V
(AC 250 V; DC 50 V UL/CSA)
3.5...16 A
3.5...8 A 1000 operations at 2 x IN
10...16 A 50 operations at 2 x IN
-20...+60 °C (-4...+140 °F) T 60
Rated impulse Pollution
withstand voltage degree
2.5 kV
2
reinforced insulation in operating area
Test voltage
AC 3,000 V
> 100 MΩ (DC 500 V)
3.5... 8 A 8 x IN
10...16 A 120 A
IN
3.5...16 A
3.5 ... 7A
8 ...16 A
UN
DC 50 V
AC 250 V
AC 250 V
200 A
1,000 A
2,000 A
operating area IP 40
terminal area IP 00
10 g (57-500 Hz) ±0.76 mm (10-57 Hz),
to IEC 60068-2-6, Test Fc,
10 frequency cycles/axis
25 g (11 ms)
to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH
to IEC 60068-2-3, test Ca
approx. 10 g
Approvals
Authority
VDE
UL / CSA
Semko
Kema (EN 60934)
Voltage ratings
AC 240 V; DC 28 V
AC 250 V; DC 50 V
AC 240 V
AC 240 V; DC 48 V
Current ratings
7 ...16 A
3.5...16 A
7 ...16 A
3.5...16 A
All dimensions without tolerances are for reference only. In the interest of improved design,
performance and cost effectiveness the right to make changes in these specifications without
notice is reserved.Product markings may not be exactly as the ordering codes. Errors and
omissions excepted.
Issue C
☎ USA (847) 827-7600 - CANADA (905) 764-9510